IBM Support

HE01433: Workbench Drafting abends with CLICK OK TO TERMINATE if CATReffi lesPath is very long

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • SCENARIO
    1.Create a very long path for Reffiles and paste that folder in
    C > Documents and Settings > Temp
    2. Go to CATIA's Environment Editor and edit the CATReffilesPath
     and assign the address of the above created folder.
    3.Start CATIA V5
    4.Create a new Drawing in Drafting workbench.
    5.CATIA V5 Abends with error message "Click OK to terminate"
    .
    Result:
    CATIA V5 Abends with error message "Click OK to terminate"
    .
    Expected Result:
    CATIA V5 Should not abend and create a new drawing
    SCENARIO:
    CATIA's Environment Editor allows the CATReffilesPath to be edit
    ed to a very long value (e.g. 1865 characters).
    1.Open TEST_CATIA.txt file provided by customer.
    2.Copy the DC5 folder and paste it to  C > Documents and Setting
    s > Temp.
    3.Copy the path in Reffiles.
    4.Open the CATenv file and at your end and paste the path.
    5.Start CATIA V5
    6.Create a new Drawing in Drafting workbench.
    7.CATIA V5 Abends with error message "Click OK to terminate"
    .
    Result:
    CATIA V5 Abends with error message "Click OK to terminate"
    .
    Expected Result:
    CATIA V5 Should not abend and create a new drawing
    Other Info:
    Case reported on CATIA V5 R19 SP04
    Case also reproduced at latest CATIA V5 R20 Build Date(10-29-10)
    Case also reproduced at latest CATIA V5 R21 Build Date(10-29-10)
    

Local fix

  • empty
    

Problem summary

  • SCENARIO
    1.Create a very long path for Reffiles and paste that folder
    in C > Documents and Settings > Temp
    2. Go to CATIA's Environment Editor and edit the
    CATReffilesPath and assign the address of the above created
    folder.
    3.Start CATIA V5
    4.Create a new Drawing in Drafting workbench.
    5.CATIA V5 Abends with error message "Click OK to terminate"
    .
    Result:
    CATIA V5 Abends with error message "Click OK to terminate"
    .
    Expected Result:
    CATIA V5 Should not abend and create a new drawing
    SCENARIO:
    CATIA's Environment Editor allows the CATReffilesPath to be
    edited to a very long value (e.g. 1865 characters).
    1.Open TEST_CATIA.txt file provided by customer.
    2.Copy the DC5 folder and paste it to  C > Documents and
    Settings > Temp.
    3.Copy the path in Reffiles.
    4.Open the CATenv file and at your end and paste the path.
    5.Start CATIA V5
    6.Create a new Drawing in Drafting workbench.
    7.CATIA V5 Abends with error message "Click OK to terminate"
    .
    Result:
    CATIA V5 Abends with error message "Click OK to terminate"
    .
    Expected Result:
    CATIA V5 Should not abend and create a new drawing
    Other Info:
    Case reported on CATIA V5 R19 SP04
    Case also reproduced at latest CATIA V5 R20 Build
    Date(10-29-10)
    Case also reproduced at latest CATIA V5 R21 Build
    Date(10-29-10)
    

Problem conclusion

  • NOTE THAT THIS PROBLEM WILL BE FIXED ON CATIA V5R20 SP7.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON CATIA V5R21 SP2.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON CATIA V5-6R2012
    SP1
    Additional Closure Information:
    INCIDENT DIAGNOSIS:
    Open Drafting and CATIA abends if CATReffilesPath is very long
    .
    TECHNICAL EXPLANATION OF THE DEFECT:
    CATIA was crashing  if CATReffilesPATH is very long.
    .
    TECHNICAL EXPLANATION OF THE CORRECTION:
    The code has been fixed and very long path for
    CATReffilesPath is now taken care of.
    .
    POSSIBLE BY-PASS AND/OR CORRECTION LIMITATION:
    -
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE01433

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    519

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-10-29

  • Closed date

    2011-11-29

  • Last modified date

    2011-11-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R520 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
29 November 2011