  • Scenario:
    1. Open CATIA Imagine and Shape workbench.
    2. Create a triangle surface using triangle icon.
    3. Activate ???view and selection mode???.
    4. Click on ???vertex selection??? icon from the tools palette
    and try to select any vertex of triangle.
    Problem:
    Vertex does not get selected. When we try to select vertex
    from the opposite face of triangle, then the vertex gets
    selected.
    Expected Result:
    Vertices of triangle should get selected from the front face
    of triangle, i.e., the visible face.
    

Local fix

  • empty
    

Problem summary

  • Scenario:
    1. Open CATIA Imagine and Shape workbench.
    2. Create a triangle surface using triangle icon.
    3. Activate ???view and selection mode???.
    4. Click on ???vertex selection??? icon from the tools palette
    and try to select any vertex of triangle.
    Problem:
    Vertex does not get selected. When we try to select vertex
    from the opposite face of triangle, then the vertex gets
    selected.
    Expected Result:
    Vertices of triangle should get selected from the front face
    of triangle, i.e., the visible face.
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON Virtual Design  VERSION V5R21
    GA level.
    Additional Closure Information:
    Incident Diagnosis:
    Orientation of new triangle surface is reversed.
    Technical explanation of the defect:
    Must set the edges in reverse order. Needs product
    versionning.
    Technical explanation of the correction:
    The edges are created counter-clockwise now.
    Possible by-pass and/or correction limitation:
    None.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE01347

  • Reported component name

    CATIA V5 WIN 64

  • Reported component ID

    569165000

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-10-27

  • Closed date

    2010-12-13

  • Last modified date

    2010-12-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 WIN 64

  • Fixed component ID

    569165000

Applicable component levels

  • R521 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
13 December 2010