IBM Support

HE00067: A CATIA R19 CATDRAWING CREATED ON WINDOWS 64-BIT CAN BE OPENED ON WINDOWS 32-BIT ONLY

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • Scenario:
    1) Start 64-bit CATIA V5R19SP3 on Windows 64bit
    2) Open the CATDrawing
    -> It is not possible to open the drawing
    -> The following error message appears:
    .
    Problem while reading document. Load operation failed
    Invalid data. No editor associated
    .
    3) Start  CATIA V5R19SP3 on Windows 32bit
    4)  Open the CATDrawing
    -> It is possible to load the CATDrawing
    -> The following error message appaers:
    .
    Standards have not been loaded for document??
    because of data inconsistency
    .
    ****************************************************************
    *************************************
    DS ONLY
    Problem reproduced using 64-bit CATIA R21 under windows 64-bit.
    After Open and Save using 32-bit CATIA R21 under windows 32-bit,
    the resulting drawing can be opened using 64-bit CATIA R21 under
     windows 64-bit.
    .
    ABK
    

Local fix

  • empty
    

Problem summary

  • Scenario:
    1) Start 64-bit CATIA V5R19SP3 on Windows 64bit
    2) Open the CATDrawing
    -> It is not possible to open the drawing
    -> The following error message appears:
    .
    Problem while reading document. Load operation failed
    Invalid data. No editor associated
    .
    3) Start  CATIA V5R19SP3 on Windows 32bit
    4)  Open the CATDrawing
    -> It is possible to load the CATDrawing
    -> The following error message appaers:
    .
    Standards have not been loaded for document??
    because of data inconsistency
    .
    **************************************************************
    ***************************************
    DS ONLY
    Problem reproduced using 64-bit CATIA R21 under windows
    64-bit.
    After Open and Save using 32-bit CATIA R21 under windows
    32-bit,
    the resulting drawing can be opened using 64-bit CATIA R21
    under windows 64-bit.
    .
    ABK
    

Problem conclusion

  • Incident Diagnosis:
    Analysis shows that the problem is caused by the CEG1
    drafting standard in the drawing.
    The development team have replaced the invalid standard with
    the ISO standard and the corrected drawing is available.
    Note:
    Further investigation will be made if the customer can
    providde the CEG1.xml file and the scenario that results in
    the problematic drawing.
    .
    THIS PROBLEM IS A PERMANENT RESTRICTION
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE00067

  • Reported component name

    CATIA V5 WIN 64

  • Reported component ID

    569165000

  • Reported release

    519

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-09-14

  • Closed date

    2012-04-24

  • Last modified date

    2012-04-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
24 April 2012