APAR status
Closed as program error.
Error description
1) Open the Harness Product. 2) In Electrical iXF Data Repository choose the folder containing xml file 3) In "Electrical Wire Routing" with "Select External System" function use the system xml and put in Current Systems and OK 4) With "Automatic Wire Routing" function generate wire group and wire 5) Update the whole structure 6) The wire diameter=10mm and Bend Radius =60mm 7) Edit manually in local the xml file, put diameter=0.02 and Bend Radius = 0.08, save the xml file 8) With "Select External System" function select the system XML and put It back in Available Systems and OK 9) With "Select External System" function select the system XML and put in Current Systems and OK 10) With "Automatic Wire Routing" function generate wire group and wire . Problem: The wire group diameter=10mm and Bend Radius =60mm (Values not updated) . Bypass: 12) Delete the whole wire group with wire 13) With "Automatic Wire Routing" function generate wire group with wire 14) Update the whole structure 15) The wire group diameter=20mm and Bend Radius =80mm (Values updated)
Local fix
empty
Problem summary
1) Open the Harness Product. 2) In Electrical iXF Data Repository choose the folder containing xml file 3) In "Electrical Wire Routing" with "Select External System" function use the system xml and put in Current Systems and OK 4) With "Automatic Wire Routing" function generate wire group and wire 5) Update the whole structure 6) The wire diameter=10mm and Bend Radius =60mm 7) Edit manually in local the xml file, put diameter=0.02 and Bend Radius = 0.08, save the xml file 8) With "Select External System" function select the system XML and put It back in Available Systems and OK 9) With "Select External System" function select the system XML and put in Current Systems and OK 10) With "Automatic Wire Routing" function generate wire group and wire . Problem: The wire group diameter=10mm and Bend Radius =60mm (Values not updated) . Bypass: 12) Delete the whole wire group with wire 13) With "Automatic Wire Routing" function generate wire group with wire 14) Update the whole structure 15) The wire group diameter=20mm and Bend Radius =80mm (Values updated)
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION V5R21 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19 SP9. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP4. Additional Closure Information: Technical explanation of the defect: Wire Group attributes not valuated correctly after modifying the xml file. . Technical explanation of the correction: Error in code. Wire Group attributes are now valuated correctly after modifying the xml file.
Temporary fix
Comments
APAR Information
APAR number
HD99662
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
519
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-08-31
Closed date
2010-09-14
Last modified date
2010-09-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R519 PSN