Error description
Scenario: 1)Open specific CATpart containing certain Boolean operations. 2)Go measure inertia command. 3)select a partbody under specific Boolean operations. Problem: CATIA shows error "selection not valid". Expected result: CATIA should not throw error.Inertia should be calculated.
Local fix
empty
Problem summary
Scenario: 1)Open specific CATpart containing certain Boolean operations. 2)Go measure inertia command. 3)select a partbody under specific Boolean operations. Problem: CATIA shows error "selection not valid". Expected result: CATIA should not throw error.Inertia should be calculated.
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA Additional Closure Information: Incident Diagnosis: Cannot compute mass properties Reason: It seems that the different PCurves used to delimit face 5587 are defined outside the U, V limits of the underlying sphere surface. This is not an authorized configuration and explains the error. Note that any other operator requiring the face???s 2D bounding box will also trigger the same error. By-Pass: None
Temporary fix
Comments
APAR Information
APAR number
HD99435
Reported component name
CATIA V5 WIN 64
Reported component ID
569165000
Reported release
519
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-08-24
Closed date
2011-08-03
Last modified date
2011-08-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
03 August 2011