Error description

  • ABSTRACT:
    Measure does not get updated when accessed through Catalog.
    .
    SCENARIO:
    1. Start CATIA V5R19SP5 and go to Tools/Options/Parameters and M
    easure/Measure Tools tab and enable "Automatic update in part".
    2. Open "SamplePart.CATPart" that has the following characterist
    ics:
     a. One PartBody composed of a single Pad
     b. Assigned material Aluminum
     c. Inertia Measure named InertiaVolume.1
     d. Parameter Mass.1 that reports mass volume from InertiaVolume
    .1
     e. Parameter PartLength corresponding to a dimension on the pad
    
     f. Parameter PartNumber
     g. Design table with 5 configurations. Two columns: PartNumber,
     Length (Reference SamplePartDT.xls)
    3. Note the mass value under InertiaVolume.1.
    3. Create new Catalog Document.
    4. Click ???Add Part Family??? and click ???Select Part Document
    ???. Select SamplePart.CATPart file. Click OK.
    5. In catalog document, Right click on any configuration and sel
    ect "Open New Document". A new document is created and opened.
    6. Note the mass value under InertiaVolume.1.
    The reported mass in the measurement InertiaVolume.1 is 0lb. Con
    sequently the Mass.1 parameter displays 0lb. The measurement can
    not be updated. Editing the InertiaVolume.1 measure indicates th
    at there is no selection. An accurate, updated value is expected
    .
    .
    RESULT:
    The reported mass in the measurement InertiaVolume.1 is "0". The
     Mass value is not updated when it is accessed through Catalog.
    .
    EXPECTED RESULT:
    The Mass value should be accurate & updated when it is accessed
    through Catalog.
    

Local fix

  • empty
    

Problem summary

  • ABSTRACT:
    Measure does not get updated when accessed through Catalog.
    .
    SCENARIO:
    1. Start CATIA V5R19SP5 and go to Tools/Options/Parameters
    and Measure/Measure Tools tab and enable "Automatic update in
    part".
    2. Open "SamplePart.CATPart" that has the following
    characteristics:
     a. One PartBody composed of a single Pad
     b. Assigned material Aluminum
     c. Inertia Measure named InertiaVolume.1
     d. Parameter Mass.1 that reports mass volume from
    InertiaVolume.1
     e. Parameter PartLength corresponding to a dimension on the
    pad
     f. Parameter PartNumber
     g. Design table with 5 configurations. Two columns:
    PartNumber, Length (Reference SamplePartDT.xls)
    3. Note the mass value under InertiaVolume.1.
    3. Create new Catalog Document.
    4. Click ???Add Part Family??? and click ???Select Part Document
    ???.
    Select SamplePart.CATPart file. Click OK.
    5. In catalog document, Right click on any configuration and
    select "Open New Document". A new document is created and
    opened.
    6. Note the mass value under InertiaVolume.1.
    The reported mass in the measurement InertiaVolume.1 is 0lb.
    Consequently the Mass.1 parameter displays 0lb. The
    measurement cannot be updated. Editing the InertiaVolume.1
    measure indicates that there is no selection. An accurate,
    updated value is expected.
    .
    RESULT:
    The reported mass in the measurement InertiaVolume.1 is "0".
    The Mass value is not updated when it is accessed through
    Catalog.
    .
    EXPECTED RESULT:
    The Mass value should be accurate & updated when it is
    accessed through Catalog.
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION V5R21 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP5.
    Additional Closure Information:
    Incident Diagnosis
    Measure Does Not Update When Avccessed Through Catalog.
    Correction Explanation
    There was a problem with building the Rep which was causing
    the issue. This problem is now corrected.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD98612

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    519

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-07-23

  • Closed date

    2010-12-21

  • Last modified date

    2010-12-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R521 PSN

       UP