  • Scenario: (Data Specific)
    1. Start CATIA.
     2. Open CATPart
     3. Switch workbench to Generative Structural Analysis.
     4. Select "Static Analysis" as New Analysis Case.
     5. Edit parameters of the mesh as:
     6. On Global tab, set the values "Size: 5mm" and "Absolute sag:
     2mm". Then select "Parabolic" as Element type.
     7. Switch to Local tab, then select "Edge distribution" and cli
    ck "add" button.
     8. Select the Edge and click "OK" button.
     9. Select "Imposed points" and select the point. Then, click "O
    K" button.
    10. Click "OK" button of OCTREE Tetrahedron Mesh window.
    11. Compute mesh.
    Problem:
    CATIA crashes or freezes while computing mesh.
    Expected Result:
    Mesh should be computed properly
    

Local fix

  • empty
    

Problem summary

  • Scenario: (Data Specific)
     1. Start CATIA.
     2. Open CATPart
     3. Switch workbench to Generative Structural Analysis.
     4. Select "Static Analysis" as New Analysis Case.
     5. Edit parameters of the mesh as:
     6. On Global tab, set the values "Size: 5mm" and "Absolute
    sag: 2mm". Then select "Parabolic" as Element type.
     7. Switch to Local tab, then select "Edge distribution" and
    click "add" button.
     8. Select the Edge and click "OK" button.
     9. Select "Imposed points" and select the point. Then, click
    "OK" button.
    10. Click "OK" button of OCTREE Tetrahedron Mesh window.
    11. Compute mesh.
    Problem:
    CATIA crashes or freezes while computing mesh.
    Expected Result:
    Mesh should be computed properly
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION V5R21 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP4.
    Additional Closure Information:
    Incident Diagnosis:
    CATIA abends or freezes when computing the Mesh.
    Technical explanation of the defect:
    Bug in imposed nodes management
    Technical explanation of the correction:
    Incompatibility between specs (imposed point and
    distribution) is removed.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD98426

  • Reported component name

    CATIA V5 WIN 64

  • Reported component ID

    569165000

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-07-19

  • Closed date

    2010-08-03

  • Last modified date

    2010-08-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 WIN 64

  • Fixed component ID

    569165000

Applicable component levels

  • R520 PSN

       UP