APAR status
Closed as duplicate of another APAR.
Error description
Scenario: 1: Create the following structure Product.CATProduct |-Skeleton.CATPart |-Part1.CATpart |-Part2.CATpart 2. Create an Assembly annotation Set in the Skeleton.CATPart 3. Create one FTA view (Section for exemple) 4. Create one Capture called "ALL". 5. Create two other captures called "capture1" and "capture2". 6. Make sure that all captures have the "Manage the visibility o f part instances, bodies and geometrical sets" option On. (Captu re Properties>Capture Attributes). 7. Active "Capture1", define CATPart2 as no show. 8. Active "Capture2" , define CATPart1 as no show 9. Active Capture "all" and define all CATParts as no show. Problem: Switching from 1 capture to another doesn't respect the show/noshow status defined in each captures. Expected Result: Switching from 1 capture to another doesn't res pect the show/noshow status defined in each captures.
Local fix
empty
Problem summary
Scenario: 1: Create the following structure Product.CATProduct |-Skeleton.CATPart |-Part1.CATpart |-Part2.CATpart 2. Create an Assembly annotation Set in the Skeleton.CATPart 3. Create one FTA view (Section for exemple) 4. Create one Capture called "ALL". 5. Create two other captures called "capture1" and "capture2". 6. Make sure that all captures have the "Manage the visibility of part instances, bodies and geometrical sets" option On. (Capture Properties>Capture Attributes). 7. Active "Capture1", define CATPart2 as no show. 8. Active "Capture2" , define CATPart1 as no show 9. Active Capture "all" and define all CATParts as no show. Problem: Switching from 1 capture to another doesn't respect the show/noshow status defined in each captures. Expected Result: Switching from 1 capture to another doesn't respect the show/noshow status defined in each captures.
Problem conclusion
THE PROBLEM HAS BEEN FOUND TO BE ANOTHER SYMPTOM OF THE PROBLEM REPORTED IN APAR HD98271 OR THE ANSWER MADE FOR THIS DUPLICATE APAR APPLIES ALSO TO THE CURRENT PROBLEM. Additional Closure Information: Incident Diagnosis: Its an enhancement with a limitation. By-Pass: 1. For the Part Instances whose geometries are not referenced by the annotations under the Assembly Annotation Set in which the capture is created; the Show/Hide property will not be handled by the capture. 2. The setting in Tools -> Options -> Infrastructure -> Part Infrastructure -> General Tab: - Keep link with selected object - Show newly created external references must be set before creating annotation under Assembly Annotation Set. If the setting is not done, the Part Instance management will not be happen with the capture in Assembly Annotation Set.
Temporary fix
Comments
This APAR is a duplicate of HD98271
APAR Information
APAR number
HD98380
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
519
Status
CLOSED DUA
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-07-16
Closed date
2011-08-30
Last modified date
2011-08-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 WIN 64
Fixed component ID
569165000
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
30 August 2011