APAR status
Closed as program error.
Error description
SCENARIO: 1. Start CATIA. 2. Select ???Tools / Options.??? 3. Select ???Options / Mechanical Design / Functional Toleranc ing & Annotation / Tolerancing??? tab. 4. Switch ???Default standard at creation??? to ???ISO_3D.??? 5. Select ???Options / Mechanical Design / Functional Toleranc ing & Annotation / Tolerances??? tab. 6. See ???General tolerance class.??? Its is seen that the class is switched to ISO class. 7. Go back to ???Tolerancing??? tab. 8. Switch ???Default standard at creation??? to ???ASME_3D.??? 9. Go back to ???Tolerances??? tab. It is seen that ???General tolerance class??? is switched to ANSI class. 10. Launch Explore and go to ???install directory of V5\ inte l_a\resources\standard\drafting??? directory. 11. Copy ???ASME_3D.xml??? and paste it in the same directory with the name of ???ASME_3D_TEST.xml.??? 12. Or go to Tools/Standards - create a new standard from ASME _3D with name- ???ASME_3D_TEST". 13. Open ???Options??? dialog box again and go to ???Options / Mechanical Design / Functional Tolerancing & Annotation / Tol erancing??? tab. 14. Switch ???Default standard at creation??? to ???ASME_3D_TE ST.??? 15. Go to ???Options / Mechanical Design / Functional Toleranc ing & Annotation / Tolerances??? tab. RESULTS:: The ???General tolerance class??? is not switched to ANSI class. EXPECTED RESULT: The item of ???General tolerance class??? should be switched t o ANSI class: ( ???ANSI B4.3-1978-f,??? ???ANSI B4.3-1978-m,??? and ???ANSI B4 .3-1978-c??? ) in the list, when the standard that was duplicated from the ori ginal ???ASME_3D.xml??? is selected.
Local fix
empty
Problem summary
SCENARIO: 1. Start CATIA. 2. Select ???Tools / Options.??? 3. Select ???Options / Mechanical Design / Functional Tolerancing & Annotation / Tolerancing??? tab. 4. Switch ???Default standard at creation??? to ???ISO_3D.??? 5. Select ???Options / Mechanical Design / Functional Tolerancing & Annotation / Tolerances??? tab. 6. See ???General tolerance class.??? Its is seen that the class is switched to ISO class. 7. Go back to ???Tolerancing??? tab. 8. Switch ???Default standard at creation??? to ???ASME_3D.??? 9. Go back to ???Tolerances??? tab. It is seen that ???General tolerance class??? is switched to ANSI class. 10. Launch Explore and go to ???install directory of V5\ intel_a\resources\standard\drafting??? directory. 11. Copy ???ASME_3D.xml??? and paste it in the same directory with the name of ???ASME_3D_TEST.xml.??? 12. Or go to Tools/Standards - create a new standard from ASME_3D with name- ???ASME_3D_TEST". 13. Open ???Options??? dialog box again and go to ???Options / Mechanical Design / Functional Tolerancing & Annotation / Tolerancing??? tab. 14. Switch ???Default standard at creation??? to ???ASME_3D_TE ST.??? 15. Go to ???Options / Mechanical Design / Functional Tolerancing & Annotation / Tolerances??? tab. RESULTS:: The ???General tolerance class??? is not switched to ANSI class. EXPECTED RESULT: The item of ???General tolerance class??? should be switched t o ANSI class: ( ???ANSI B4.3-1978-f,??? ???ANSI B4.3-1978-m,??? and ???ANSI B4.3-1978-c??? ) in the list, when the standard that was duplicated from the original ???ASME_3D.xml??? is selected.
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION V5R21 GA level. Additional Closure Information: INCIDENT DIAGNOSIS: The item of General tolerance class is not switched correctly when the standard that was duplicated from the original standard is selected. TECHNICAL EXPLANATION OF PROBLEM: The Tolerance class is switched between ASME/ISO based on the Tools / Options / FTA / Tolerance Standard. But the parent standard was not considered. TECHNICAL EXPLANATION OF CORRECTION: Two different tolerance classes drop down selection boxes are provided corresponding to ASME and ISO standard possibilities. The same is done for Linear, Angular and Chamfer dimension Tolerance general classes. User can change these two selection boxes independently, while creating the annotation with the tolerance. In this case the tolerance class value corresponding to the annotation set original standard will be considered. If the annotation set has an ASME derived standard and a Linear dimension with the General tolerance is created: Then the value displayed in the Limit of Size panel will be initialized with the corresponding value of ASME selection box from the Tools / Options / FTA / Tolerances / Linear tolerance / ASME selection box value.
Temporary fix
Comments
APAR Information
APAR number
HD98336
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
519
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-07-15
Closed date
2010-12-09
Last modified date
2010-12-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R520 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
09 December 2010