  • SCENARIO:
    1. Create a Run and place a Valve on it
    2. Insert a new Product, and using 3DCopu/Paste command, copy
    Run and valve into sub-product
    3. Save ALL data and close
    4. Create a new product and using insert document inser valve
    (that has been saved in previous step)
    5. Using Build part command change attribute value of
    EndStyle and save data and close.
    6. Open data saved in step 3 and check Attribute Value
    endstyle for each instance
    CONCERN: EndStyle value of copied valve is NOT updated (sync)
    

Local fix

  • empty
    

Problem summary

  • SCENARIO:
    1. Create a Run and place a Valve on it
    2. Insert a new Product, and using 3DCopu/Paste command, copy
    Run and valve into sub-product
    3. Save ALL data and close
    4. Create a new product and using insert document inser valve
    (that has been saved in previous step)
    5. Using Build part command change attribute value of
    EndStyle and save data and close.
    6. Open data saved in step 3 and check Attribute Value
    endstyle for each instance
    CONCERN: EndStyle value of copied valve is NOT updated (sync)
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA V5R21 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP4.
    Additional Closure Information:
    Technical explanation of the defect:
    Link between copied instance and reference is
    somehow not maintained. Relinking instance with
    reference part document using Edit->Links command
    resolves the issue. But thorough code its not
    possible for us due to limited exposed functionality
    Technical explanation of the correction:
    issue is resolved by two methods:
    a) For Instances in Session:At exit of Build Part
    Command, when attribute on reference is modified ,
    all instances in session will be checked and their
    attributes will be compared with reference
    attribute value. Mismatched attribute values will
    be updated on instances.
    b) For instances OUT of Session: A Design Validation check is
    provided which will sync instance attribute values
    with those of reference.
    NOTE: In both cases, only those attributes will be
    synced which are
    a) not propagated from line ID,
    b) which are modifiable and defined on reference.
    Possible by-pass and/or correction limitation:
    After instance is copied using "Copy/Paste 3D
    system" command, goto Edit->Links and relink the
    copied instance to its reference part document (
    user needs to do this even if the instance is seen
    to be pointing to the correct reference part
    document).
    The scenario is OK if this relinking.
    is done.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD96308

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-05-13

  • Closed date

    2010-09-14

  • Last modified date

    2010-09-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R520 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
14 September 2010