APAR status
Closed as program error.
Error description
SCENARIO: 1. Create a Run and place a Valve on it 2. Insert a new Product, and using 3DCopu/Paste command, copy Run and valve into sub-product 3. Save ALL data and close 4. Create a new product and using insert document inser valve (that has been saved in previous step) 5. Using Build part command change attribute value of EndStyle and save data and close. 6. Open data saved in step 3 and check Attribute Value endstyle for each instance CONCERN: EndStyle value of copied valve is NOT updated (sync)
Local fix
empty
Problem summary
SCENARIO: 1. Create a Run and place a Valve on it 2. Insert a new Product, and using 3DCopu/Paste command, copy Run and valve into sub-product 3. Save ALL data and close 4. Create a new product and using insert document inser valve (that has been saved in previous step) 5. Using Build part command change attribute value of EndStyle and save data and close. 6. Open data saved in step 3 and check Attribute Value endstyle for each instance CONCERN: EndStyle value of copied valve is NOT updated (sync)
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA V5R21 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP4. Additional Closure Information: Technical explanation of the defect: Link between copied instance and reference is somehow not maintained. Relinking instance with reference part document using Edit->Links command resolves the issue. But thorough code its not possible for us due to limited exposed functionality Technical explanation of the correction: issue is resolved by two methods: a) For Instances in Session:At exit of Build Part Command, when attribute on reference is modified , all instances in session will be checked and their attributes will be compared with reference attribute value. Mismatched attribute values will be updated on instances. b) For instances OUT of Session: A Design Validation check is provided which will sync instance attribute values with those of reference. NOTE: In both cases, only those attributes will be synced which are a) not propagated from line ID, b) which are modifiable and defined on reference. Possible by-pass and/or correction limitation: After instance is copied using "Copy/Paste 3D system" command, goto Edit->Links and relink the copied instance to its reference part document ( user needs to do this even if the instance is seen to be pointing to the correct reference part document). The scenario is OK if this relinking. is done.
Temporary fix
Comments
APAR Information
APAR number
HD96308
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-05-13
Closed date
2010-09-14
Last modified date
2010-09-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R520 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: