APAR status
Closed as program error.
Error description
Scenario :- Configurations of SmarTeam: - Option 'Save derived configurations' in SmarTeam SolidWorks integration is disabled. - Create first part and save to SmarTeam (SWP-0405.sldprt, Active part) - Create second part and save to SmarTeam (SWP-0406.sldprt, Suppressed part) - Create assembly, insert both SMP-0405.sldprt and SWP-0406.sldprt. - Suppress part SWP-0406.sldprt in assembly - Create derived configuration in assembly, but reactivate default configuration. - Save assembly to SmarTeam (SWA-0113.sldasm, Assembly with derived config and suppressed part) - Check-in assembly and parts. - Open assembly read-only. The active part will also be copied to the workdirectory, but the suppressed part not. - Select the suppressed part in the SolidWorks feature manager tree, and click the 'Open' icon. The SmarTeam integration will detect the missing file and will ask if it should look for it in the SmarTeam database. Choose 'Yes'. The suppressed part is copied from the vault and opened in SolidWorks - Close the assembly and the part. - Delete the file of the suppressed part using the Windows Explorer, not the SmarTeam File Explorer! - The suppressed part will be marked 'Absent' in the SmarTeam File Explorer. - Open the assembly. - Switch to the DMT. Only the assembly is shown. - Click on the assembly in the DMT using the right mouse button and choose 'Refresh. - The tree is now complete [This is Current Result] Note:-The number of times you have to refresh the DMT is dependent on the number of suppressed components in the assembly.
Local fix
empty
Problem summary
Scenario :- Configurations of SmarTeam: - Option 'Save derived configurations' in SmarTeam SolidWorks integration is disabled. - Create first part and save to SmarTeam (SWP-0405.sldprt, Active part) - Create second part and save to SmarTeam (SWP-0406.sldprt, Suppressed part) - Create assembly, insert both SMP-0405.sldprt and SWP-0406.sldprt. - Suppress part SWP-0406.sldprt in assembly - Create derived configuration in assembly, but reactivate default configuration. - Save assembly to SmarTeam (SWA-0113.sldasm, Assembly with derived config and suppressed part) - Check-in assembly and parts. - Open assembly read-only. The active part will also be copied to the workdirectory, but the suppressed part not. - Select the suppressed part in the SolidWorks feature manager tree, and click the 'Open' icon. The SmarTeam integration will detect the missing file and will ask if it should look for it in the SmarTeam database. Choose 'Yes'. The suppressed part is copied from the vault and opened in SolidWorks - Close the assembly and the part. - Delete the file of the suppressed part using the Windows Explorer, not the SmarTeam File Explorer! - The suppressed part will be marked 'Absent' in the SmarTeam File Explorer. - Open the assembly. - Switch to the DMT. Only the assembly is shown. - Click on the assembly in the DMT using the right mouse button and choose 'Refresh. - The tree is now complete [This is Current Result] Note:-The number of times you have to refresh the DMT is dependent on the number of suppressed components in the assembly.
Problem conclusion
NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19 SP8. Additional Closure Information: PER
Temporary fix
Comments
APAR Information
APAR number
HD95323
Reported component name
SMARTEAM NT>XP
Reported component ID
569199970
Reported release
519
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-04-12
Closed date
2010-05-12
Last modified date
2010-06-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SMARTEAM NT>XP
Fixed component ID
569199970
Applicable component levels
R519 PSN SP51908
UP10/06/10 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS2S3T","label":"ENOVIA SmarTeam V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: