APAR status
Closed as program error.
Error description
1. Open the provided CATProduct 2. Select the cgr 3. Activate 3D-Cut in DMU Optimizer Workbench 4. Change the size of the cutting box) 5. If you use the "Visual Feedback" on the "Definition" Tab you can see the sectioning is working 6. Activate the preview and you will see nothing 7. If you try to save the cutted geometry you will receive a empty cgr-file
Local fix
empty
Problem summary
1. Open the provided CATProduct 2. Select the cgr 3. Activate 3D-Cut in DMU Optimizer Workbench 4. Change the size of the cutting box) 5. If you use the "Visual Feedback" on the "Definition" Tab you can see the sectioning is working 6. Activate the preview and you will see nothing 7. If you try to save the cutted geometry you will receive a empty cgr-file
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION V5R21 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19 SP8. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP2. Additional Closure Information: The problem is now well corrected. The cutted geometry appear now in the window.
Temporary fix
Comments
APAR Information
APAR number
HD94744
Reported component name
ENOVIA V5 VPM N
Reported component ID
569151400
Reported release
519
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-03-22
Closed date
2010-04-06
Last modified date
2010-06-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ENOVIA V5 VPM N
Fixed component ID
569151400
Applicable component levels
R519 PSN SP51908
UP10/06/10 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS7P2G","label":"ENOVIA V5 VPM Discipline"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
10 June 2010