IBM Support

HD94535: SECONDARY WINDOW CLOSES AFTER CLICKING OK IN SECTIONING TOOL IN ASSEMBLY DESIGN

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • ABSTRACT:
    DMUSPA: Secondary Window closes after clicking OK in
    Sectioning tool in Assembly Design
    SCENARIO:
    1. Launch CATIA with MD2 license.
    2. Open any CATProduct.
    3. Go to Assembly Design workbench.
    4. Click on 'sectioning' command.
    5. In 'sectioning definition' window go to Result tab.
    6. Click on volume cut option.
    7. Check that Secondary window is active.
    8. Click OK in 'sectioning definition' window
    RESULT:
    The Secondary window (Section cut window) closes immediately.
    EXPECTED RESULT:
    The Secondary window (Section cut window) should be active
    after step8.
    

Local fix

  • empty
    

Problem summary

  • ABSTRACT:
    DMUSPA: Secondary Window closes after clicking OK in
    Sectioning tool in Assembly Design
    SCENARIO:
    1. Launch CATIA with MD2 license.
    2. Open any CATProduct.
    3. Go to Assembly Design workbench.
    4. Click on 'sectioning' command.
    5. In 'sectioning definition' window go to Result tab.
    6. Click on volume cut option.
    7. Check that Secondary window is active.
    8. Click OK in 'sectioning definition' window
    RESULT:
    The Secondary window (Section cut window) closes immediately.
    EXPECTED RESULT:
    The Secondary window (Section cut window) should be active
    after step8.
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA
    Additional Closure Information:
    Incident Diagnosis:
    Secondary Window closes after clicking OK in Sectioning tool
    in Assembly Design
    Restriction Explanation:
    In case of section feature persistency (meaning whether
    section will be presistent/retained in visualization,
    specification tree & also section result window is kept) on
    clicking OK in section dialog is dependent on specific
    licences only.
    This section feature persistency behavior will be available
    only with products (.prd) like DU1, DN1 (for P1 licences) and
    DMN, DMU (for P2 licences). Since MD2 does not authorize any
    of the above, behavior will be seen as currently.
    Please use the mentioned licenses to get this feature
    available.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD94535

  • Reported component name

    CATIA V5 WIN 64

  • Reported component ID

    569165000

  • Reported release

    519

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-03-15

  • Closed date

    2010-03-25

  • Last modified date

    2010-03-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
25 March 2010