Error description
Scenario: 1. Open Catia V5 2. Open Tools-Options, select MD2 and sharable ST1 license 3. Check in General-Compatibility-STEP page that, the option one step file is selected for Assemblies. 4. Select Tools Utility 5. Select Batch DXF-IGES-STEP 6. Fill in the form, select Catia V5 parts or products 7. Select Licensing options MD2 and ST1 8. Select Options Step page . Result: It s not possible to edit Assemblies options (This is the error) . Expected Result: It should be possible to edit Assemblies options when converting cad models to step, using batch utility with the ST1 sharable license.
Local fix
empty
Problem summary
Scenario: 1. Open Catia V5 2. Open Tools-Options, select MD2 and sharable ST1 license 3. Check in General-Compatibility-STEP page that, the option one step file is selected for Assemblies. 4. Select Tools Utility 5. Select Batch DXF-IGES-STEP 6. Fill in the form, select Catia V5 parts or products 7. Select Licensing options MD2 and ST1 8. Select Options Step page . Result: It s not possible to edit Assemblies options (This is the error) . Expected Result: It should be possible to edit Assemblies options when converting cad models to step, using batch utility with the ST1 sharable license.
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA Additional Closure Information: Incident Diagnosis: Settings for step conversion doesn't work when using batch utility with the ST1 sharable license selected. . Restriction Explanation: When the licenses for step conversion are selected from the batch mode as well as interactive mode, CATIA is unable to identify which sharable license is to be used and therefore some of the options are not available in the batch panel. The only method to rectify this issue was to remove the check of the license in the STEP option from the batch panel.However, in the current algorithm defined for editing the STEP option there is no such provision made to identify whether the action (license selection) is done from the CATIA interactive session or from the batch panel. So it is not possible to remove the check. . By-Pass: 1) Select ST1 shareable in interactive mode 2) Tools/options/STEP select right options for batch conversion 3) Release ST1 shareable 4) Tools/Utility 5) Select ST1 shareable for the batch 6) DO NOT SELECT STEP OPTIONS(STEP settings previously defined interactively will be taken) 7) Run batch
Temporary fix
Comments
APAR Information
APAR number
HD92639
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
518
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-01-15
Closed date
2010-03-12
Last modified date
2010-03-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
12 March 2010