HD92639: SETTINGS FOR STEP CONVERSION DOESN'T WORK WHEN USING BATCH UT IL ITY WITH THE ST1 SHARABLE LICENSE SELECTED.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • Scenario:
    1. Open Catia V5
    2. Open Tools-Options, select MD2 and sharable ST1 license
    3. Check in General-Compatibility-STEP page that, the
    option one step file is selected for Assemblies.
    4. Select Tools Utility
    5. Select Batch DXF-IGES-STEP
    6. Fill in the form, select Catia V5 parts or products
    7. Select Licensing options MD2 and ST1
    8. Select Options Step page
    .
    Result: It s not possible to edit Assemblies options (This is
    the error)
    .
    Expected Result:
    It should be possible to edit Assemblies options when
    converting cad models to step, using batch utility with the
    ST1 sharable license.
    

Local fix

  • empty
    

Problem summary

  • Scenario:
    1. Open Catia V5
    2. Open Tools-Options, select MD2 and sharable ST1 license
    3. Check in General-Compatibility-STEP page that, the
    option one step file is selected for Assemblies.
    4. Select Tools Utility
    5. Select Batch DXF-IGES-STEP
    6. Fill in the form, select Catia V5 parts or products
    7. Select Licensing options MD2 and ST1
    8. Select Options Step page
    .
    Result: It s not possible to edit Assemblies options (This is
    the error)
    .
    Expected Result:
    It should be possible to edit Assemblies options when
    converting cad models to step, using batch utility with the
    ST1 sharable license.
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA
    Additional Closure Information:
    Incident Diagnosis:
    Settings for step conversion doesn't work when using batch
    utility with the ST1 sharable license selected.
    .
    Restriction Explanation:
    When the licenses for step conversion are selected from the
    batch mode as well as interactive mode, CATIA is unable to
    identify which sharable license is to be used and therefore
    some of the options are not available in the batch panel.
    The only method to rectify this issue was to remove the check
    of the license in the STEP option from the batch
    panel.However, in the current algorithm defined for editing
    the STEP option there is no such provision made to identify
    whether the action (license selection) is done from the CATIA
    interactive session or from the batch panel.
    So it is not possible to remove the check.
    .
    By-Pass:
    1) Select ST1 shareable in interactive mode
    2) Tools/options/STEP select right options for batch
    conversion
    3) Release ST1 shareable
    4) Tools/Utility
    5) Select ST1 shareable for the batch
    6) DO NOT SELECT STEP OPTIONS(STEP settings previously
    defined interactively will be taken)
    7) Run batch
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD92639

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    518

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-01-15

  • Closed date

    2010-03-12

  • Last modified date

    2010-03-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 March 2010