IBM Support

HD91214: CATIA V5 TUBING INCORRECT MINTANGENTLENGTH SELECTION

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Scenario:
    1. Launch the Tubing workbench of CATIA V5 R19 SP3
    2. Click on Route a Run
        - The run command displays the Turn Rules depending upon
    the current line ID value.
    3. Select the appropriate row in the table
    Result:
    When the user picks up one of the rows in the Turn rules
    table, the bending rules tables will be searched for the
    corresponding Minimum Tangent Length.
    Concern:
    As per current implementation the code picks up the first
    match from the bending rule table.
    Expected Result:
    A list of matching rows from the bending rule table should be
    displayed so that the user can pick the suitable result.
    

Local fix

  • empty
    

Problem summary

  • Scenario:
    1. Launch the Tubing workbench of CATIA V5 R19 SP3
    2. Click on Route a Run
        - The run command displays the Turn Rules depending upon
    the current line ID value.
    3. Select the appropriate row in the table
    Result:
    When the user picks up one of the rows in the Turn rules
    table, the bending rules tables will be searched for the
    corresponding Minimum Tangent Length.
    Concern:
    As per current implementation the code picks up the first
    match from the bending rule table.
    Expected Result:
    A list of matching rows from the bending rule table should be
    displayed so that the user can pick the suitable result.
    

Problem conclusion

  • NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19 SP7.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP2.
    Additional Closure Information:
    Technical explanation of the defect:
    When the user picks up one of the rows in the Turn rules
    dialog during run routing, the bending rules table will be
    searched for selected Nominal Size and Bend Radius
    combination and the corresponding Minimum Tangent Length is
    registered for further run routing. As per current
    implementation the code picks up the first match from the
    bending rule table. Hence user is not able to set different
    MinTangent Length even if entries are made in Bending rule
    text file.
    Technical explanation of the correction:
    With this enhancement, the bending rule panel is displayed to
    the user if there are multiple entries in Bending rule text
    file for selected combination of Nominal Size and Bend
    radius. The user can interactively select a row from the
    panel to set the min tangent length.
    Note:
    This enhancement is delivered under a flag.
    The user needs to set this environment flag equal to 1 in
    order to display the bending rule table.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD91214

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    519

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-11-27

  • Closed date

    2010-02-15

  • Last modified date

    2010-02-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R519 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
15 February 2010