HD88607: FSS: SURFACIC CURVATURE ANALYSIS COLOR DISPLAY RESULT IS NOT OK WHEN FIXED 3D ACCURACY=0.02

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • SCENARIO:
    1. Start CATIA V5
    2. Open the CATPart.
    Workbench:
    Freestyle
    3. Click Shading with Material icon.
    View mode is
    changed.
    4. Confirm that Fixed 3D accuracy=0.20 at Tools /
    Option / general / display / Performance
    5. Double click the
    Surfacic Curvature Analysis.1 from specification
    tree.
    Surfacic Curvature Analysis window is opened.
    6. Please
    select following
    Type- -Minimum
    Display Options
    Color
    Scale-activate
    On The Fly-activate
    Analysis Options
    Positive
    only-activate
    Radius Mode- activate
    7. Select the EdgeFillet.4
    or Geometry.
    Observation: Display result is Ok
    8. Go to Tools
    / Option / general / display / Performance and change Fixed 3D
    accuracy to 0.02 or 0.01
    9. Repeat steps 5 to7
    .
    PROBLEM:
    A
    surface connection checker color display result is not OK at
    the portion where two or more fillets are connected.
    

Local fix

Problem summary

  • SCENARIO:
    1. Start CATIA V5
    2. Open the CATPart.
    Workbench:
    Freestyle
    3. Click Shading with Material icon.
    View mode is
    changed.
    4. Confirm that Fixed 3D accuracy=0.20 at Tools /
    Option / general / display / Performance
    5. Double click the
    Surfacic Curvature Analysis.1 from specification
    tree.
    Surfacic Curvature Analysis window is opened.
    6. Please
    select following
    Type- -Minimum
    Display Options
    Color
    Scale-activate
    On The Fly-activate
    Analysis Options
    Positive
    only-activate
    Radius Mode- activate
    7. Select the EdgeFillet.4
    or Geometry.
    Observation: Display result is Ok
    8. Go to Tools
    / Option / general / display / Performance and change Fixed 3D
    accuracy to 0.02 or 0.01
    9. Repeat steps 5 to7
    .
    PROBLEM:
    A
    surface connection checker color display result is not OK at
    the portion where two or more fillets are connected.
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA
    Additional
    Closure Information:
    INCIDENT DIAGNOSIS: Color display result
    of Surfacic curvature analysis is incorrect when fixed 3D
    accuracy=0.02 or 0.01
    RESTRICTION EXPLANATION:
    The surfacic
    curvature analysis computes the minimum radius on each
    location of tessellation. When 3D accuracy= 0.20, there are
    less triangles and hence less number of locations while
    computing the minimum radius compared to that when 3D accuracy
    is 0.02 or 0.01
    This can be observed by visualizing the
    geometry in triangles.
    When 3D accuracy=0.20, all the
    locations are on points where the surfacic curvature is
    greater or equal to 2mm and hence it is shown in correct
    corresponding color.
    However when 3D accuracy=0.02 or 0.01,
    more number of points are taken into consideration while
    computing the result. Some of these points are smaller than
    2mm. Hence surfacic curvature shows some area in different
    color.
    Note that the geometric accuracy of all geometric
    elements is 0.001mm. However it is not the case that fillet
    radius will be exactly 2mm everywhere.
    The geometric
    resolution of 0.001mm or even the numerical resolution
    (approximately 10e-12) can compute the result as 2.0000000001
    or 1.999999 and therefore curvature display result is shown in
    different colors just due to this precision phenomenon.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD88607

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    519

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-09-09

  • Closed date

    2009-10-06

  • Last modified date

    2009-10-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
06 October 2009