  • SCENARIO:
    Start CATIA V5
    Disable the option "Load referenced documents" in Tools /
    Options / General
    1. Open the attached CATProduct
    .
    OBSERVATION:
    Some of the CATProducts are seen as loaded
    .
    .
    

Local fix

Problem summary

  • SCENARIO:
    Start CATIA V5
    Disable the option "Load referenced documents" in Tools /
    Options / General
    1. Open the attached CATProduct
    .
    OBSERVATION:
    Some of the CATProducts are seen as loaded
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA
    Additional Closure Information:
    Incident Diagnosis:
    Some Products are loaded even after deactivating the option
    -"Load reference documents"
    .
    Technical Reason:
    The Products are loaded partially (selective loading) and not
    in Design Mode.
    This is because Products contain constraint information
    related to the Part level and these constraints are resolved
    at the Part level.
    However, in the customer data the Parts having these
    constraints are missing.So, eventually the constraints
    attempt to load the Product partially.
    .
    CATDUA cleaning for the constraints is possible.
    This information is stored at Part level and the cleaning is
    also therefore done on the Part level.If the Parts are
    available, the corruption is cleaned and after these cleaned
    Parts are again loaded, the Products are synchronized with
    these Parts.
    However, in customer data the Parts are missing , so cleaning
    cannot be done and therefore CATDUA does not solve the issue.
    .
    The customer provided data contains insufficient information
    for providing a fix or a solution on the data.This is the
    problem with data and not the code or CATIA. So, the issue is
    closed as PERMANENT RESTRICTION.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD88011

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    518

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-08-18

  • Closed date

    2009-11-27

  • Last modified date

    2009-11-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
27 November 2009