IBM Support

IJ02233: LUA APPLICATION HANG ON NODE STARTUP

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Communications Server for Data Center Deployment on AIX, V7
    -----------------------------------------------------------
    An LUA application using the deprecated "application scheduling"
    method of managing multiple sessions will occasionally encounter
    a hang on some of those sessions when "sna stop; sna start" is
    issued while the application is running. The application does
    not receive the BIND RQ or SDT RQ that CommServer received from
    the mainframe, so does not know to respond.
    

Local fix

  • Stop the LUA application. Stop/restart SNA. Restart the LUA
    application.
    

Problem summary

  • An LUA application using the deprecated "application scheduling"
    method of managing multiple sessions will occasionally
    encounter a hang on some of those sessions when "sna stop; sna
    start" is issued while the application is running. The
    application does not receive the BIND RQ or SDT RQ that
    CommServer received from the mainframe, so does not know to
    respond.
    
    The problem occurs when the single-threaded application using
    appplication scheduling stays running during a recycling of the
    SNA node and the SNA library is trying to generate logs (in this
    case an exception log to report the failure of RUI_INIT).
    

Problem conclusion

  • A change has been made to the CS/AIX library to prevent this
    problem from occurring. A return code COMM_SUBSYSTEM_NOT_LOADED
    will be returned when an application first reissues RUI_INIT
    after the "sna stop".
    

Temporary fix

  • Stop the LUA application. Stop/restart SNA. Restart the LUA
    application.
    

Comments

APAR Information

  • APAR number

    IJ02233

  • Reported component name

    CS DCD AIX 7.X

  • Reported component ID

    5725H3200

  • Reported release

    700

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-12-04

  • Closed date

    2018-01-18

  • Last modified date

    2018-06-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CS DCD AIX 7.X

  • Fixed component ID

    5725H3200

Applicable component levels

  • R700 PSY U880995

       UP18/06/14 I 1000

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSKK8Z","label":"Communications Server for Data Center Deployment"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"700"}]

Document Information

Modified date:
23 September 2021