Fixes are available
APAR status
Closed as program error.
Error description
Customer installed Pcomm 6.0.6 on many Windows7 32bit PCs and often encounters a trap in PCSWS.EXE process when start up a 5250 session. The session window is displayed, however, the PS is blank and see the message "PCSWS.EXE stop running" It occurs intermittently.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All 5250 emulator users with Quick Connect * * Bar enabled. * **************************************************************** * PROBLEM DESCRIPTION: When Quick Connect Bar (QCB) is * * enabled on 5250 emulator sessions, an * * intermittent crash occurs. If Quick * * Connect Bar is disabled, there is no * * crash. * **************************************************************** * RECOMMENDATION: * **************************************************************** When the Quick Connect Bar is enabled for 5250 emulator sessions and a Workstation ID is used, the emulator session may crash at startup. The crash occurs while updating the Workstation ID field in the QCB.
Problem conclusion
PCSWS.EXE and PCSCLIB.DLL have been changed by adding a Workstation update function when only the Workstation ID field of the QCB needs to be updated. Fix scheduled for PCOM 6.0.9 Refresh Pack
Temporary fix
Comments
APAR Information
APAR number
IC96940
Reported component name
PCOMM V5 COMBO-
Reported component ID
5639I7000
Reported release
601
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-10-16
Closed date
2013-10-24
Last modified date
2013-12-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PCSCLIB PCSWS
Fix information
Fixed component name
PCOMM V5 COMBO-
Fixed component ID
5639I7000
Applicable component levels
R601 PSY
UP
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSEQ5Y","label":"Personal Communications"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]