IC96940: PCOM: PCSWS STOPS RUNNING WHEN STARTING 5250 SESSIONS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Customer installed Pcomm 6.0.6 on many Windows7 32bit PCs and
    often encounters a trap in PCSWS.EXE process when start up a
    5250 session. The session window is displayed, however, the PS
    is blank and see the message "PCSWS.EXE stop running"
    It occurs intermittently.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All 5250 emulator users with Quick Connect   *
    *                 Bar enabled.                                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: When Quick Connect Bar (QCB) is         *
    *                      enabled on 5250 emulator sessions, an   *
    *                      intermittent crash occurs. If Quick     *
    *                      Connect Bar is disabled, there is no    *
    *                      crash.                                  *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When the Quick Connect Bar is enabled for 5250 emulator
    sessions and a Workstation ID is used, the emulator session
    may crash at startup. The crash occurs while updating the
    Workstation ID field in the QCB.
    

Problem conclusion

  • PCSWS.EXE and PCSCLIB.DLL have been changed by adding a
    Workstation update function when only the Workstation ID
    field of the QCB needs to be updated.
    
    Fix scheduled for PCOM 6.0.9 Refresh Pack
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC96940

  • Reported component name

    PCOMM V5 COMBO-

  • Reported component ID

    5639I7000

  • Reported release

    601

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-10-16

  • Closed date

    2013-10-24

  • Last modified date

    2013-12-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IC98096 IC98097 IC98098 IP23671

Modules/Macros

  • PCSCLIB  PCSWS
    

Fix information

  • Fixed component name

    PCOMM V5 COMBO-

  • Fixed component ID

    5639I7000

Applicable component levels

  • R601 PSY

       UP

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSEQ5Y","label":"Personal Communications"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]