Fixes are available
APAR status
Closed as program error.
Error description
When using a subflow with a number of references where the reference value differs between the main flow and the subflow, the incorrect value of the reference name may be returned resulting in a CWSXM3700E: exception.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: Users of WebSphere Enterprise Service Bus v6.2 or v7, WebSphere Process Server v6.2 and BPM v7 who use subflows with references. **************************************************************** PROBLEM SUMMARY: When a reference within a subflow is references using a different alias than that used in the main flow then when the flow is built the reference may not be found. This is due to the flow builder using the alias from the subflow rather than the reference name from the main flow.
Problem conclusion
The code was modified such that the correct reference name is used within the subflow. The code fix was targeted to be included in the following fixpacks: 6.2.0 Fix Pack 4 (v6.2.0.4) 7.0.0 Fix Pack 6 (v7.0.0.6) 7.5.1 Fix Pack 2 (v7.5.1.2)
Temporary fix
Comments
APAR Information
APAR number
IC96100
Reported component name
WEB ESB FOR WIN
Reported component ID
5724I8200
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-09-19
Closed date
2013-09-26
Last modified date
2013-09-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEB ESB FOR WIN
Fixed component ID
5724I8200
Applicable component levels
R620 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7J6S","label":"WebSphere Enterprise Service Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]