APAR status
Closed as program error.
Error description
When you install Sterling B2B Integrator V5.2.4, Fix Pack 1, it fails to remove an obsolete CDJava.jar file, which causes issues with the Connect Direct Server adapter upin starting Sterling B2b Integrator after installing the fixd pack.
Local fix
Remove the reference to the obsolete CDJava.jar file from dynamicclasspath.cfg and rename the obsolete CDJava.jar on the file system.
Problem summary
PROBLEM SUMMARY Users Affected: Sterling B2B Integrator 5.2 customers applying a fix pack on top of an interim fix. Problem Description: After upgrading from an interim fix to V5.2.4, Fix Pack 1 Connect:Direct Server adapter will not start. Platforms affected: All
Problem conclusion
PROBLEM CONCLUSION Resolution Summary: The Interim Fix installation process was not aware of other versions of the CDJava third-party jar the might have been installed as a result of a previous Interim Fix. Code fix applied that identifies and removes previous or obsoleted versions of the CDJava.jar before installing the new version. Delivered In: 5020500_2
Temporary fix
Comments
APAR Information
APAR number
IC95926
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
524
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-09-12
Closed date
2015-02-16
Last modified date
2015-02-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
R524 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.4","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
20 February 2015