APAR status
Closed as program error.
Error description
SCC monitoring is unstable. SCC show the server is down ,but it is not down. We pause the monitor,resume the monitor after seconds ,it will be stable for hours.
Local fix
STRRTC - 354078 SF / SF Circumvention: None
Problem summary
Description of issue: When SCC does a select stat command, error returned, bad/invalid process name. SCC the nodes monitoring is unstable.SCC can show the server is down, but it is not down. This was caused by allowing the limit to exceed 99,999.
Problem conclusion
Description of fix: Set limit at 99,999 (instead of 999,999).
Temporary fix
Published fix package and notified customer.
Comments
Published fix package and notified customer.
APAR Information
APAR number
IC87592
Reported component name
STR CONTROL CEN
Reported component ID
5725D0200
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-10-29
Closed date
2012-11-26
Last modified date
2012-11-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR CONTROL CEN
Fixed component ID
5725D0200
Applicable component levels
R52X PSY
UP
R530 PSY
UP
R540 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9GLA","label":"IBM Control Center"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]