IBM Support

IC80614: DATAPOWER DOES NOT RENDER THE DEFAULT VALUE FOR DATATYPE "XSD:DOUBLE" CORRECTLY

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If a "xsd:double" datatype is defined with an identified
    default in a schema used by DataPower, for example:
    
    <xsd:attribute name="attribute_1" use="optional"
    default="123.0">
    
    and a request is sent to the DataPower service using the schema,
    triggering a response with the default value for "attribute_1",
    the response message may consider an unexpected value.  For
    example:
    
    attribute_1="0.0E0"
    
    instead of
    
    attribute_1="123.0".
    

Local fix

  • Depending on use case, "xsd:float" may be a suitable substitute
    in place of "xsd:double".
    

Problem summary

  • Affected is the use of optional Schema default values of type
    "xs:double".
    
    The default value is not honored and 0.0E0 shows up by
    default.
    

Problem conclusion

  • Fix is available in 3.8.2.11, 4.0.1.8 and 4.0.2.4.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC80614

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    402

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-01-04

  • Closed date

    2012-02-28

  • Last modified date

    2012-03-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R382 PSY

       UP

  • R401 PSY

       UP

  • R402 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.0.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]