IBM Support

IC75163: PROCESSING JSON TYPE MESSAGE MAY FAIL DUE TO MESSAGE LENGTH RESTRICTIONS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When processing JSON traffic data, if any name/value pair has a
    string length considered too long, the service will fail and a
    log message similar to the following will be registered, with
    error code 0x80c00008:
    
    "implied action convert-http: 'Converting INPUT with map (none)
    results stored in __JSONASJSONX' failed: JSON type length
    exceeded"
    
    This is due to an internal limit of 256 characters for any
    string value or 128 characters for any number value.
    

Local fix

  • Until the internal limitation is pushed higher or made
    configurable, the suggestion is to reduce the length of the
    value being passed.
    

Problem summary

  • Affected are customers making use of JSON string processing of
    "long" strings.
    
    
    The service will fail and a log message
    will be registered, with error code 0x80c00008.
    
    This is due to an internal limit of 256 characters for any
    string value or 128 characters for any number value.
    

Problem conclusion

  • Maximum supported JSON property name and value length of 8192
    are available in 3.8.1.11 and 3.8.2.3
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC75163

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    381

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-03-21

  • Closed date

    2011-04-15

  • Last modified date

    2011-04-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R381 PSY

       UP

  • R382 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]