APAR status
Closed as program error.
Error description
Preliminary installation. V6R2 0CG0. C84 Controller, 783 terminal Terminal 31 load fails at W065 Preload Failure B5/S250/E255. I have deleted and rebuilt all preload bundles and rebuilt loadshrink without success. 03/07 08:17 CC 031 2 W065 PRELOAD FAILURE B5/S250/E255 SOURCE: Terminal Preload Client UNIQUE DATA: 1F4000800000000000000000000000000000 *.@................* . The data gives the return code 8000401F - Stack Fault Occurred
Local fix
Problem summary
Access the HOSTS file with the gethostent() which uses the inet_addr() and causes a Stack fault if an IP address entry has an extra period.
Problem conclusion
Change the validation that keeps track of the number of periods in the string to avoid writing outside the array to prevent stack fault.
Temporary fix
Correct the error in the HOSTS file.
Comments
APAR Information
APAR number
IO20839
Reported component name
IBM 4690 OS V6
Reported component ID
5639P7000
Reported release
201
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-03-13
Closed date
2014-06-27
Last modified date
2014-08-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
TCPIP ADXHSISL
Fix information
Fixed component name
IBM 4690 OS V6
Fixed component ID
5639P7000
Applicable component levels
R301 PSY
UP
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SOULYT","label":"Point of Sale Software->4690 Operating System"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"201","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
28 August 2014