IJ21797: PRODUCT NAME AND PRODUCT VERSION MISSING FOR WEBLOGIC INSTANCES

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • For certain Weblogic instances, product name and product
    version are not set as shallow details are loaded from XML
    config file. So, if XML has these fields missing, these values
    aren't set.
    For weblogic discovery, in order to control the
    shallow details , a boolean collation property has been
    introduced.
    If the property is set to false then shallow
    details are not stored in the result of the sensor and if set
    to true, then shallow details are stored.
    
    For Weblogic
    Launcher Sensor,
    to stop the shallow details to store in the db
    , configure com.ibm.cdb.discover.app.j2ee.weblogic.sensor.Weblog
    icLauncher.storeShallow to false
    For Weblogic Application
    Senor,
    to stop the shallow details to store in the db,
    configure com.ibm.cdb.discover.app.j2ee.weblogic.sensor.Weblogic
    Application.storeShallow to false
    

Local fix

  • N/A
    

Problem summary

  • For certain Weblogic instances, product name and product
    version are not set as shallow details are loaded from XML
    config file. So, if XML has these fields missing, these values
    aren't set.
    For weblogic discovery, in order to control the shallow details
    , a boolean collation property has been introduced. If the
    property is set to true then shallow details are not stored in
    the result of the sensor and if set to false(which is the
    default value), then shallow details are stored.
    Collation is
    com.ibm.cdb.discover.app.j2ee.weblogic.sensor.skipShallow
    Possible values are  true  and  false . Default
    value is false.
    If you want to stop storing shallow details of weblogic,  then
    set it as
    com.ibm.cdb.discover.app.j2ee.weblogic.sensor.skipShallow=true
    

Problem conclusion

  • The fix for this APAR is contained in the following maintenance
    packages: |FixPack|7.3.0-ITV-ITADDM-FP0007
    

Temporary fix

  • NA
    

Comments

APAR Information

  • APAR number

    IJ21797

  • Reported component name

    APP DEPENDENCY

  • Reported component ID

    5724N5500

  • Reported release

    730

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-12-30

  • Closed date

    2020-02-23

  • Last modified date

    2020-02-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • 999
    

Fix information

  • Fixed component name

    APP DEPENDENCY

  • Fixed component ID

    5724N5500

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"}, "Product":{"code":"SSPLFC","label":"Tivoli Application Dependency Discovery Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"730","Edition":""}]

Document Information

Modified date:
23 February 2020