Error description

  • Integrity Checker reports that every text-based (ALN,UPPER,
    LOWER) Maximo column is defined incorrectly.  For example:
    BMXAA0443E -- Error - BMXAA0494E -- The definition of this
    column does not match the actual column. The native column
    definition does not match the servers metadata. Run the
    Integrity Checker in repair mode.
    BMXAA6841I -- PERSONCAL.SHIFTNUM, Maximo definition is
    UPPER(8), Database column is UPPER(16)
    Integrity Checker no longer considers maxvar VARCHARMULTIPLE,
    which is used to support multi-byte character sets.  If
    VARCHARMULTIPLE=2, then all database columns should be created
    as twice the Maximo-defined length.  .  If VARCHARMULTIPLE=3,
    then all database columns should be created as three times the
    Maximo-defined length.  In the above example,
    VARCHARMULTIPLE=2, length of native column PERSONCAL.SHIFTNUM
    (16) is twice the Maximo-defined length of the column (8), yet
    Integrity Checker reports the column is incorrectly defined.
    
    STEPS TO REPRODUCE:
    Install or upgrade to Maximo 7.6.1.  Run Integrity Checker in
    report-only mode.  Note the thousands of errors that are
    reported.
    
    EXPECTED RESULTS:
    Consistently defined columns should not be reported as errors.
    
    PRODUCT VERSION:
    Maximo Asset Management 7.6.1
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Maximo Users on 761                                          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * The VARCHARMULTIPLE MaxVar was read incorrectly and not      *
    * defaulted correctly when missing.                            *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fixpack Release 7.6.1.0 of Base Services, or request   *
    * an interim fix                                               *
    ****************************************************************
    

Problem conclusion

  • Fix has been made to correctly read the VARCHARMULTIPLE MaxVar
    and handle cases where the value is missing or not a number.
    
    The fix for this APAR is contained in the following maintenance
    package:
    | release\fix pack\interim fix for Release 7.6.1.0 of Base
    Services
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ11277

  • Reported component name

    UPGRADE PROGRAM

  • Reported component ID

    5724R46UP

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-11-13

  • Closed date

    2019-02-19

  • Last modified date

    2019-02-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • MAXIMO
    

Fix information

  • Fixed component name

    UPGRADE PROGRAM

  • Fixed component ID

    5724R46UP

Applicable component levels

  • R761 PSY

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCHPPD","label":"Upgrade Programs"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
19 February 2019