  • Closed as program error.

Error description

  • If you have a rate limit interval set to be a multiple of days
    (and therefore be divisible by 24 hours), you may see that the
    count of API calls is not correctly reset leading to 429 (Rate
    Limit exceeded) errors.
    Another issue noticed is that X-RateLimit-Remaining header in
    API Header is not showing correct value.
    For instance if there is a plan with 2000 calls per day and in
    the analytic you can see how many calls a client has made to
    that plan (for  example 300).
    Then making an API Call, you will notices in the
    X-RateLimit-Remaining header,  the number is more than 1700.
    

Local fix

  • Define Product plans with ratel limit of 22 or 23 hours instead
    of calls per day or 24 hours.
    

Problem summary

  • SLM rate limit policy is not working correctly for daily
    intervals.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT28426

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    760

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-03-12

  • Closed date

    2019-04-26

  • Last modified date

    2019-04-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"}, "Product":{"code":"SSCXUFY","label":"General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"760","Edition":""}]

Document Information

Modified date:
26 April 2019