Error description
With PCOM 6.0.10 level, the APPEND Transfer Type would allow the user to add data to a PC text file. With PCOM 12.0.2 level, this option no longer works. The PC text file is replaced each time a new file is downloaded.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All IBM Personal Communications users * **************************************************************** * PROBLEM DESCRIPTION: * * When using £IND$FILE transfer of file from Host to PC, * * the PC file always gets overwritten when transfer type is * * set to append. * **************************************************************** * RECOMMENDATION: * **************************************************************** Steps to recreate the problem: 1) Open a PCOMM emulator session and connect to 3270 Host 2) Select £Receive File From Host from Actions menu 3) Browse for Host File name and PC File name 4) Select the £Transfer Type to be append and click Add to list 5) Click Ok Appending fails and the existing file in the PC will be overwritten.
Problem conclusion
While receiving a file from Host to PC, a new file gets created irrespective of the Transfer Type selected resulting in the existing file contents getting lost. PCSXFER.DLL has been changed. If the PC file already exists and if the £Transfer type is append, a new file will not be created and appending will be performed. Fix is scheduled for PCOM 12.0.4.0 Refresh Pack and 13.0.1.1 Fix Pack.
Temporary fix
Comments
APAR Information
APAR number
IT24835
Reported component name
PCOMM COMBO-ENG
Reported component ID
5639I7000
Reported release
C00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-04-24
Closed date
2018-05-17
Last modified date
2019-02-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PCSXFER
Fix information
Fixed component name
PCOMM COMBO-ENG
Fixed component ID
5639I7000
Applicable component levels
RC00 PSY
UP
RD00 PSY
UP
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSEQ5Y","label":"Personal Communications"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C00"}]
Document Information
Modified date:
28 September 2021