IT06724: PUREAPPLICATION SYSTEM: THE SYSTEM CONSOLE MAY REPORT MORE SPACE THAN IS AVAILABLE FOR DEPLOYMENTS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • On PureApplication System version 1.1.0.4 and lower deployments
    may fail with the following error:
    
    'CWZIP2436W No suitable storage pool was found on which to
    place a new storage volume'
    
    The System Console reports that there is available
    space for deployment. This is due to incorrect resource
    reporting.
    

Local fix

Problem summary

  • The storage reported in the System Console was incorrect. The
    value appeared to report enough storage for deployments which
    would then fail to deploy due to lack of storage.
    

Problem conclusion

  • The System Console storage controller detail has been updated
    to report "Physical storage utilization" and "Physical storage
    allocation" in PureApplication System version 2.0.0.0.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT06724

  • Reported component name

    PAPP SYS 8382 I

  • Reported component ID

    5725G3200

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-01-23

  • Closed date

    2015-02-26

  • Last modified date

    2015-02-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    PAPP SYS 8382 I

  • Fixed component ID

    5725G3200

Applicable component levels

  • R200 PSY

       UP

  • R210 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSM8NY","label":"PureApplication System"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: