IBM Support

IT03846: NETWORK VLAN CONFIGURATION FAILS DUE TO A "MISMATCHED PORT SETTINGS" ERROR.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • An error can be encountered when performing network
    configuration activities on the PureApplication System.  This
    can also be seen when completing the network setup activities
    for the system when it is first setup at the customer site.
    Below is an example of errors that might be seen during the SGEN
    process.   Error code 403
    
    -----
    pooljvm.1405430196748.113 [01-01-14 14:38:49] 39879
    global_config.cgen | value of exception:
    VGENUtilities.GenesisException: RackXXXX-XXX 1000000: Errors
    were found while verifying the top-of-rack switches.
    pooljvm.1405430196748.113 [01-01-14 14:38:49] 39879
    global_config.cgen | RackXXXX-XXX 1000000: Errors were found
    while verifying the top-of-rack switches.
    pooljvm.1405430196748.113 [001-01-14 14:38:49] 39879
    global_config.cgen | RackXXXX-XXX 1000000 TOR 1 (bottom, Rack
    Unit 41): Errors were found during verification.
    pooljvm.1405430196748.113 [01-01-14 14:38:49] 39879
    global_config.cgen | RackXXXX-XXX 1000000 TOR 1 (bottom, Rack
    Unit 41): The current configuration does not match the
    predefined configuration. Contact IBM Service.
    pooljvm.1405430196748.113 [01-01-14 14:38:49] 39879
    global_config.cgen | Mismatched Configuration Entry: Interface
    port settings (interface port 64): There are entries for this
    command in the current configuration file. However, none of them
    have settings which match the expected file settings:
    [description "Port 64", switchport mode trunk, switchport trunk
    native vlan 999, switchport trunk allowed vlan 1,2867,999,
    exit].
    -----
    

Local fix

Problem summary

  • The network configuration verification process was raising false
    switch configuration error events and then exiting the
    verification stage.
    

Problem conclusion

  • A fix is being provided to log the "switch mismatched
    configuration" error and continue the system verification
    process.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT03846

  • Reported component name

    PAPP SYS 8382 I

  • Reported component ID

    5725G3200

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-08-19

  • Closed date

    2014-09-11

  • Last modified date

    2014-09-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    PAPP SYS 8382 I

  • Fixed component ID

    5725G3200

Applicable component levels

  • R110 PSY

       UP

  • R200 PSY

       UP

  • R100 PSN

       UP

  • RESP PSN

       UP