Error description
When samadapter is manually configured by running mksamadapter without parameters then samadapter-make file is created. If this is executed messages are displayed such as ./samadapter-make: line 15: [: -ne: unary operator expected This is because of unitialized internal variable
Local fix
None. The error messages can be ignored, if they are only of type: ./samadapter-make: line 15: [: -ne: unary operator expected
Problem summary
**************************************************************** * USERS AFFECTED: Tivoli System Automation for Multiplatforms * (SA MP) users configuring the samadapter using silent or * manual configuration **************************************************************** * PROBLEM DESCRIPTION: * The script 'mksamadapter' creates the script 'samadapter-make' * with syntax errors. The execution of this created script does * create the resources as expected, but shows errors like: * ./samadapter-make: line 15: [: -ne: unary operator expected * The script 'mksamadapter' needs to be adjusted to create a * correct script 'samadapter-make'. **************************************************************** * RECOMMENDATION: ****************************************************************
Problem conclusion
The internal handling of the script mksamadapter has been adjusted to address the issue. Now it creates the script samadapter-make with correct syntax. . The official fix for this problem is included in Tivoli System Automation for Multiplatforms 3.2.2 fix pack 6. | 3.2.2-TIV-ITSAMP-FP0006 | . Additional Search Keywords .
Temporary fix
Comments
APAR Information
APAR number
IV38453
Reported component name
SA MULTIPLATFOR
Reported component ID
5724M0000
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-03-21
Closed date
2013-06-05
Last modified date
2013-06-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SA MULTIPLATFOR
Fixed component ID
5724M0000
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSRM2X","label":"Tivoli System Automation for Multiplatforms"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"320","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
25 August 2023