Direct links to fixes
4.1.1-TIV-SAMP-Linux64-FP0001
4.1.1-TIV-SAMP-AIX-FP0001
4.1.1-TIV-SAMP-Linux64-FP0000
4.1.1-TIV-SAMP-AIX-FP0000
SAMP4107_Verification_Signatures
4.1.0-TIV-SAMP-Linux64-FP0007
4.1.0-TIV-SAMP-AIX-FP0007
4.1.0-TIV-SAMP-Linux64-FP0006
4.1.0-TIV-SAMP-Linux-FP0006
4.1.0-TIV-SAMP-AIX-FP0006
4.1.0-TIV-ITSAMP-Linux64-FP0004
4.1.0-TIV-ITSAMP-Linux-FP0004
4.1.0-TIV-ITSAMP-AIX-FP0004
4.1.0-TIV-ITSAMP-FP0004, Tivoli System Automation for Multiplatforms
APAR status
Closed as program error.
Error description
BE Support Engineer: CJ Change Team Engineer: EJ SAMP: 4.1.0 Problem Description: Error messages seen in proxy syslog for xdrverifycfg like: xdrcfgver: UserID missing in output of Q SIGNALS xdrcfgver: Error when executing command vmcp "AT MYVM CMD Q SIGNALS" 2>&1,rc=512, Error=Nosuch file or directory xdrcfgver: Userids could not be retrieved on member MYVM. Error: vmcp "AT MYVM CMD Q SIGNALS"2>&1 failed with rc: 512
Local fix
N/A
Problem summary
USERS AFFECTED: Tivoli System Automation for Multiplatforms user's using GDPS Multiplatform Resiliency for System z for management of Linux on z/VM guests (xDR z/VM guest Linux on System z) ***************************** In environments with a large number of z/VM guests e.g. more than 150 guests on one z/VM system, the default buffer size for the command 'vmcp' can be too small for the output of the CP command 'q signals'
Problem conclusion
The xDR proxy code has been updated with code to handle cases, where the default buffer size for vmcp is too small for the output returned The official fix is included in Tivoli System Automation for Multiplatforms 4.1 fix pack 4 | 4.1.0-TIV-ITSAMP-FP0004 |
Temporary fix
Comments
APAR Information
APAR number
IV97314
Reported component name
SA MULTIPLATFOR
Reported component ID
5724M0000
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-06-19
Closed date
2017-06-28
Last modified date
2017-06-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SA MULTIPLATFOR
Fixed component ID
5724M0000
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSRM2X","label":"Tivoli System Automation for Multiplatforms"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
25 September 2023