Troubleshooting
Problem
SDE970CI Allocation Error Authorization Failure (SCI67662)
Symptom
SDE970CI Allocation Error Authorization Failure
ACF04056 ACCESS TO
RESOURCE volser TYPE type BY userid NOT AUTHORIZED NEW DATASET ALLOCATION FOR
VOLUME volser DENIED
IGD17012I USER NOT AUTHORIZED TO DEFINE DATA SET
data.set.name.g000nv00
Cause
SNODEID is being translated by the Authorization File to a SECID authorized for
their ACF2 security system, but the SECPWD was not valid.
Resolving The Problem
Correct SECPWD in Authorization table entry.
[{"Product":{"code":"SSFGBN","label":"IBM Sterling Connect:Direct for z\/OS"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"Not Applicable","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Historical Number
PRI32160
Product Synonym
[<p><b>]Fact[</b><p>];Connect:Direct OS/390, Release 4.3.00 [<br/>] Connect:Direct OS/390, Release
4.4.00 [<br/>] SCI67662
Was this topic helpful?
Document Information
Modified date:
17 December 2019
UID
swg21546175