APAR status
Closed as fixed if next.
Error description
Here is the error in the probe debug log: Read Thread (011673F8) 2016-06-02T08:34:53: Debug: D-ETC-004-050: THREAD MGR: thread Read Thread (011673F8) running 2016-06-02T08:34:54: Error: E-UNK-000-000: Failed to read from socket - WinSock error. Message too long. 2016-06-02T08:34:54: Debug: D-UNK-000-000: Closing UDP socket on port 514 2016-06-02T08:34:54: Error: E-P_S-102-000: Socket Error Received. Reading Thread Exitting 2016-06-02T08:34:54: Debug: D-ETC-004-051: THREAD MGR: thread Read Thread (011673F8) stopped 2016-06-02T08:34:54: Information: I-P_S-104-000: Stopping... 2016-06-02T08:34:54: Information: I-UNK-000-000: Probewatch: Going Down The reason why is the message coming to syslogd is extremely large and it caused the probe to shutdown. The probe should NOT have shut down.
Local fix
restart probe.
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of the syslogd probe on Windows. * **************************************************************** * PROBLEM DESCRIPTION: * * Log messages over 2056 characters caused the syslogd probe * * on Windows to shut down. The probe on Windows will now * * allow the long messages, but truncate them if necessary. * **************************************************************** * RECOMMENDATION: * * Upgrade to probe-nco-p-syslogd-5_4 * ****************************************************************
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
IV85644
Reported component name
SYSLOG PROBE
Reported component ID
5724P03SL
Reported release
100
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-06-13
Closed date
2016-08-29
Last modified date
2016-08-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
R100 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSSHTQ","label":"Tivoli Netcool\/OMNIbus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"100","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: