A fix is available
APAR status
Closed as program error.
Error description
"secureMain -g <GROUP> lock" leaves some files that need to writable by the group ID without group write permissions. The following files are affected: <CANDLEHOME>/<arch>/<pc>/bin/psit_*.str <CANDLEHOME>/<arch>/<pc>/bin/*_agntstat.sta <CANDLEHOME>/<arch>/<pc>/bin/*_autoattr.asa <CANDLEHOME>/<arch>/<pc>/bin/*_thresholds.xml This problem was originally reported against the MQ agent under APAR IV56725. The current PMR reports the same symptom for the UD agent. It turns out the symptom applies to any ITM agent.
Local fix
After running secureMain.sh run this command to set group write authority for situation data files: find ${CANDLEHOME} \( -name "psit_*.str" -o -name "*_agntstat.sta" -o -name "*_autoattr.asa" -o -name "*_thresholds.xml" \) -exec chmod g+w {} \;
Problem summary
On UNIX and Linux, the secureMain utility controls access to IBM Tivoli Monitoring components. The Tivoli Enterprise Monitoring Agent (TEMA) component used by all agents creates a set of files in <CANDLEHOME>/<platform>/<pc>/bin. These data files require group write access for the agent to run properly. When secureMain is used to set permissions for the component, these files are set with group read only access. The file name patterns affected are: psit_*.str, *_agntstat.sta, *_autoattr.asa, and *_thresholds.xml. When this happens, messages like the following are written to the agent log: (531F0D57.0087-B:kraapsit.cpp,1169,"writePersistSituation") Unable to open file /opt/IBM/ITM/ls3263/mq/bin/psit_XXXXXXX_xxxxxxxx_XX.str for recording, error=13
Problem conclusion
The code was changed to set group write authority for affected files. The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.3.0-TIV-ITM-FP0007
Temporary fix
Comments
APAR Information
APAR number
IV85156
Reported component name
OMEG DIST INSTA
Reported component ID
5608A41CI
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-05-25
Closed date
2016-06-27
Last modified date
2016-06-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
OMEG DIST INSTA
Fixed component ID
5608A41CI
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: