IBM Support

IV85155: LIBRARY XML FIELD MADE READONLY NOT POPULATING DATA

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Problem: In the Enter Meter Readings Dialog(Work Order Tracking
    Application),if
    the new meter reading Date and Inspector Fields are made
    readonly in
    the header  section through the application XML.  It does not
    get
    populated with the required Data.
    
    PERFORMANCE ISSUE: no
    
    STEPS TO REPRODUCE:
    Step 1.: Export the Library XML and make search for the
    Label="Enter
    Meter Reading" dialog.
    Make the  inputmode mode readonly for  fields inspector and
    newreadingdate as below.
    Import back the LIBRARY.XML.
    
    Library.xml section  after changes:
    <dialog beanclass="psdi.webclient.beans.common.AutoWogenBean"
    height="380" id="meterread" label="Enter Meter
    Readings"><tabgroup id="enterreadings"><tab default="true"
    id="enterreadings_asset" label="Asset Meter Readings"><table
    id="assetmeterread_grid_outer_1_1_meter_read" label="Asset
    Meter Readings" relationship="ACTIVEASSETMETER"><tablebody
    displayrowsperpage="20" filterable="true"
    id="assetmeterread_grid_outer_1_1_meter_read_tablebody"><tableco
    l filterable="false" hidden="false"
    id="assetmeterread_grid_outer_1_1_meter_read_tablebody_1"
    mxevent="toggledetailstate" mxevent_desc="Show Detail"
    sortable="false" type="event"/><tablecol
    dataattribute="metername"
    id="assetmeterread_grid_outer_1_1_meter_read_tablebody_2"
    sortable="true"/><tablecol dataattribute="meter.metertype"
    id="assetmeterread_grid_outer_1_1_meter_read_tablebody_3"
    linkedcontrolid="assetmeterread_grid_outer_1_1_meter_read_1_grid
    4_3" sortable="false"/><tablecol dataattribute="lastreading"
    id="assetmeterread_grid_outer_1_1_meter_read_tablebody_4"
    linkedcontrolid="assetmeterread_grid_outer_1_1_meter_read_1_grid
    4_4" sortable="false"/><tablecol
    dataattribute="lastreadingdate"
    id="assetmeterread_grid_outer_1_1_meter_read_tablebody_5"
    linkedcontrolid="assetmeterread_grid_outer_1_1_meter_read_1_grid
    4_5" sortable="false"/><tablecol dataattribute="newreading"
    id="assetmeterread_grid_outer_1_1_meter_read_tablebody_6"
    linkedcontrolid="assetmeterread_grid_outer_1_1_meter_read_1_grid
    4_6" sortable="false"/><tablecol dataattribute="newreadingdate"
    id="assetmeterread_grid_outer_1_1_meter_read_tablebody_7"
    inputmode="readonly"
    linkedcontrolid="assetmeterread_grid_outer_1_1_meter_read_1_grid
    4_7" sortable="false"/><tablecol dataattribute="dorollover"
    id="assetmeterread_grid_outer_1_1_meter_read_tablebody_9"
    linkedcontrolid="assetmeterread_grid_outer_1_1_meter_read_1_grid
    4_17" sortable="false"/><tablecol dataattribute="inspector"
    id="assetmeterread_grid_outer_1_1_meter_read_tablebody_8"
    inputmode="readonly"
    linkedcontrolid="assetmeterread_grid_outer_1_1_meter_read_1_grid
    4_8" sortable="false"/></tablebody>
    
    Step 2: Go to Work Order Tracking Application. Open any Work
    order with
    active meters associated with it .Click on Enter Meter Readings
    Select
    Action. Put a new reading in the New Reading Text Box.
    The New Reading date, Inspector fields in the HEADER section
    does not
    get populated with the System Date and Logged in User details.
    The
    details section is working as expected.
    
    
    CURRENT ERRONEOUS RESULT:
    Fields in Meter Readings header do not show up when made read
    only
    EXPECTED RESULT:
    Values in header section when made readonly should be readonly
    and visible.
    
    ADDITIONAL INFO:
    
    ENVIRONMENT (SYSTEM INFO):
    Tivoli's process automation engine
    7.6.0.3 Build 20160114-1313 DB Build V7603-151
    Best
    

Local fix

  • na
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * N/A                                                          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * LIBRARY XML FIELD MADE READONLY NOT POPULATING DATA          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Fixed in Tpae fix pack 7.6.0.6                               *
    ****************************************************************
    

Problem conclusion

  • Fixed JSP and Javascript code to make the component update ID
    match the element ID when table text is changed.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV85155

  • Reported component name

    SYSTEM CONFIG

  • Reported component ID

    5724R46S1

  • Reported release

    760

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-05-25

  • Closed date

    2016-06-09

  • Last modified date

    2016-06-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • MAXIMO
    

Fix information

  • Fixed component name

    SYSTEM CONFIG

  • Fixed component ID

    5724R46S1

Applicable component levels

  • R760 PSY

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"}, "Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"760","Edition":""}]

Document Information

Modified date:
09 June 2016