IBM Support

ABM0 abend using CMIM (SCI55987)

Troubleshooting


Problem

ABM0 abend using CMIM (SCI55987)

Symptom

Type in CMIM get blank screen and ABM0
CICS messsages are DFHAC2206 15:49:04 CICSCICS Transaction CMIM failed with abend ABM0.  Updates to local recoverable resources backed out. 

Cause

Unknown

Resolving The Problem



That abend code ABM0 is from CICS. The explanation for this code is :



The map specified for a basic mapping support (BMS) request could not be located.



Possible causes are:  



Make sure all the Connect CICS modules are in your load lib.  In Connect 1.2.0 CICS loadlib are 75 Connect members



CICS may require NEWCOPY of the map if a load failed.  A CEMT INQ of the program/map shows status REQ. When using CMIM with CEDF the load failed with a RESP2=3.  If the CICS Application Programming Reference manual, under LOAD is documented: 



A program could not be loaded because:







This was the first load of the program and the program load failed, usually because the load module could not be found.



This was a subsequent load of the program, but the first load failed.



In order to reset the load status the load module must be in the DFHRPL concatenation, and a SET PROGRAM NEWCOPY will be required

[{"Product":{"code":"SSG266","label":"IBM Sterling Connect:Enterprise for z\/OS"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"Not Applicable","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]