Error description

  • ----------------------------------------------------------------
    Severity: 2
    Approver: DK
    Compid: 5724C04TG
    Abstract: Upgraded 6.2 FP1 Hub TEMS does not shutdown properly
    when
    TEC Integration is enabled.
    
    
    Environment:
    
    Problem Description:
    
    L2 recreate: None
    Detailed Recreation Procedure:
    
    The steps that appeared to cause the failure were to:
    
    1) Validated a UA on a windows server (UA was stopped)
    2) 12:08 started UA
    3) 12:09 Imported new UA application
    4) 12:15 Refreshed UA application
    
    Observations during testing:
    
    12:03 TEPS responsive and events appearing in Omnibus
    12:15 Last omnibus event @ 12:10:09
    12:15 TEP workspace "Open Situation Counts - Last 24 Hours" goes
    blank
    and SEC stops updating
    12:40 Physical Navigator freezes then TEP client stops
    responding
    altogether.
    
    Related Files and Output:
    ---------------------------------------------------------------
    |AE 6.2.0-TIV-ITM-FP0001|
    

Local fix

  • provisional fix is available from dev.
    

Problem summary

  • When a 6.2 FP1 Hub TEMS has TEC event integration enabled, it
    does not shut down completely.  Some processes keep running,
    particularly kdsmain.
    

Problem conclusion

  • The problem was due to a counter not getting decremented to 0.
    The OTEA shutdown process would shutdown completely only after
    the counter became 0.
    
    The code has been fixed so that the counter decrements properly.
    A check has also been put in the shutdown procedure so that
    after a finite number of checks on the counter, the OTEA process
    shuts down.
    
    The fix for this APAR is contained in the following maintenance
    packages:
     | interim fix | 6.2.0.1-TIV-ITM-IF0001
    

Temporary fix

Comments

APAR Information

  • APAR number

    IZ26475

  • Reported component name

    TEC GUI INTEGRA

  • Reported component ID

    5724C04TG

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-07-07

  • Closed date

    2008-07-31

  • Last modified date

    2008-07-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    OA25898

Fix information

  • Fixed component name

    TEC GUI INTEGRA

  • Fixed component ID

    5724C04TG

Applicable component levels

  • R620 PSY

       UP