JR52094: YOU CANNOT CREATE COMPLEX TYPE FAULT MESSAGE WHEN YOU USE AN ADVANCED INTEGRATION SERVICE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When you use an Advanced Integration service, defined the
    business fault with the complex type as the fault message, and
    the response message is the designed fault with the complex
    type content, you see the following exception:
    
    javax.transaction.TransactionRolledbackException: CORBA
    TRANSACTION_ROLLEDBACK 0x0
    
    This exception prevents the business fault message from being
    returned to the process.
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  IBM Business Process Manager (BPM)          *
    *                  Advanced                                    *
    *                  IBM BPM Standard                            *
    *                  IBM BPM Express                             *
    ****************************************************************
    * PROBLEM DESCRIPTION: When you use an Advanced Integration    *
    *                      service, defined the business fault     *
    *                      with the complex type as the fault      *
    *                      message, and the response message is    *
    *                      the designed fault with the complex     *
    *                      type content, you see the following     *
    *                      exception:                              *
    *                      javax.transaction.TransactionRolledback *
    *                      Exception: CORBA                        *
    *                      TRANSACTION_ROLLEDBACK 0x0              *
    *                      This exception prevents the business    *
    *                      fault message from being returned to    *
    *                      the process.                            *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The Advanced Integration service serializes messages to invoke
    the target component.  If the simple type is used as the fault
    message, the message can be correctly serialized. If the
    complex type is used as the fault message, the  handler does
    not serialize the message and you receive the exception.
    

Problem conclusion

  • A fix is available for IBM BPM V8.5.5.0 that ensures the
    correct handler for complex type fault message is invoked in
    an Advanced Integration service.
    
    On Fix Central (http://www.ibm.com/support/fixcentral), search
    for JR52094:
    1.Select IBM Business Process Manager with your edition from
    the product selector, the installed version to the fix pack
    level, and your platform, and then click Continue.
    2.Select APAR or SPR, enter JR52094, and click Continue.
    
    When you download fix packages, ensure that you also download
    the readme file for each fix. Review each readme file for
    additional installation instructions and information about the
    fix.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR52094

  • Reported component name

    BPM ADVANCED

  • Reported component ID

    5725C9400

  • Reported release

    855

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-12-16

  • Closed date

    2015-03-16

  • Last modified date

    2015-03-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    BPM ADVANCED

  • Fixed component ID

    5725C9400

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSFTN5","label":"IBM Business Process Manager Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"855","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
31 August 2023