Fixes are available
APAR status
Closed as program error.
Error description
BigInt, '-1234567890123456789' can be inserted and read from the database, but it is being truncated like '-123456789012345678' by the MSOLEDB Plugin stage.
Local fix
Use a different data type like varchar
Problem summary
MSOLEDB Plugin was allocating 19 bytes for BigInt numbers. This is correct, except that this does not account for potential negative sign.
Problem conclusion
This patch increases the buffer length to 20 to account for potential negative sign when using very large negative numbers.
Temporary fix
Comments
APAR Information
APAR number
JR47165
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
870
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-07-08
Closed date
2013-07-16
Last modified date
2013-07-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R910 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"InfoSphere DataStage"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.7","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
12 October 2021