JR45682: TIMER EVENT WITH PROPERTY "REPEATABLE"

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • attached timer event with property "repeatable" checked and
    trigger
    relative to due date does not trigger at the correct times'.
    

Local fix

  • no local fix
    

Problem summary

  • Problem Description:
    Attached timer with repeatable flag and trigger relative to due
    date is repeated immediately after first trigger
    
    Problem Summary:
    BPM handles attached intermediate timers with repeatable flag in
    the following way:
    - When the task is started, the first execution of the timer is
    scheduled
    - Each time when a repeatable timer is triggered, it schedules
    the next execution of the timer
    When the model specifies that the timer should be triggered a
    specific interval before / after the Due Date of the
    activity or before / after a custom date, the algorithm contains
    a flaw. It calculates the scheduled time for the
    repeated firing of the event in the same way as the time for the
    first firing. This leads to the fact that after the
    first instance of the event is triggered, the calculated time
    for the next execution is already reached and the following
    instances of the event are immediately executed.
    

Problem conclusion

  • Modified the calculation for the repeated event execution. As
    soon as the date / time for the first execution is reached,
    add the specified time interval to the current time and
    reschedule the event with this target date.
    
    iFix available on top of V7511
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR45682

  • Reported component name

    BPM ADVANCED

  • Reported component ID

    5725C9400

  • Reported release

    751

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-02-08

  • Closed date

    2013-04-18

  • Last modified date

    2013-04-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    JR45687 JR45689

Fix information

  • Fixed component name

    BPM ADVANCED

  • Fixed component ID

    5725C9400

Applicable component levels

  • R751 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSFTN5","label":"IBM Business Process Manager Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.1","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
08 January 2022