Error description
Teradata Multiload stage fails to load when the input file is larger than 2 GB. If the load file is greater than 2GB, then a broken pipe error occurs. If the load file is less than 2GB in size, the mload runs fine. If the np_ directive is removed from the control file, then the mload works fine as well. Even though the Named Pipe checkbox is not selected BUT the control file still contains the AXSMOD np_axsmod.so directive. The TD stage has two check boxes as follows: 1) Use Named Pipe 2) Use Large File AXSMOD (Unix Only). In my customer's test job, the Named Pipe checkbox is not selected BUT the control file still contains the AXSMOD np_axsmod.so directive Also, the 'Large File AXSMOD' directive has not been required since around 2003 with Teradata, so there should be no need for this checkbox any more
Local fix
Manually edit the control file
Problem summary
The AXSMOD directive np_axsmod shows in the control file when the Named Pipe check box is not selected.
Problem conclusion
An environment variable was created to remove the AXSMOD directive from the control file. To remove the AXSMOD np_axsmod.so directive: Set checkpoint option to 0. Set the DS_TDM_NO_NPAXSMOD environment variable.
Temporary fix
Comments
APAR Information
APAR number
JR38744
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
810
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-01-25
Closed date
2011-05-31
Last modified date
2011-11-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R810 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"IBM InfoSphere DataStage"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
23 November 2011