IBM Support

JR38651: JOB HANGS WHEN IPC IS ENABLED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If no data has yet flowed thru the IPC link then it doen't
    respond to the stop request. This results in the job hanging.
    

Local fix

  • Disable IPC in the job.
    

Problem summary

  • For a DataStage server RealTime Job using Interprocess
    active-to-active links
    If no data has passed through the IPC link it may be
    unresponsive to a stop request.
    

Problem conclusion

  • Fixed IPC code to check for stop request when
    blocking in initial state
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR38651

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    810

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-01-13

  • Closed date

    2011-04-12

  • Last modified date