A fix is available
APAR status
Closed as program error.
Error description
The command "dsjob -run -jobstatus" incorrectly returns job status code DSJS_RESET (21).
Local fix
No workaround available.
Problem summary
**************************************************************** USERS AFFECTED: Pre-8.0.1 Fix Pack 3 DataStage users that reset jobs before running them. **************************************************************** PROBLEM DESCRIPTION: The command to reset a job, "dsjob -run -mode RESET ...", will return the status code DSJS_RESET (21) if successful. The command to run a job, "dsjob -run -jobstatus ..." should return status code DSJS_RUNOK (1) if the job ran successfully. However, when the run command is immediately preceded by the reset command the run command may incorrectly return DSJS_RESET. The incorrect code was being returned because the DSRunJob code had a start constraint which was too weak and allowed the controller job/process to proceed before the reset processing had completed. **************************************************************** RECOMMENDATION: Apply the patch for JR34329. This patch is included in 8.0.1 Fix Pack 3. ****************************************************************
Problem conclusion
The code in DSRunJob was revised to ensure that a previous job reset has completed before the job is run.
Temporary fix
Comments
APAR Information
APAR number
JR34329
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
751
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-09-22
Closed date
2011-05-04
Last modified date
2011-05-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R753 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"InfoSphere DataStage"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.1","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
11 October 2021