APAR status
Closed as program error.
Error description
If you go into DataStage Administrator and set the IPC timeout to a value different than the default of 10 seconds once you exit out and come back into the Administrator and go back to the tunables tab the timeout is reset to the default of 10 seconds. Here are the steps: - Open the DataStage Administrator - On the admin clients project tab, select the required project, and press the properties button. - Select the "Tunables" tab. - Check the "enable row buffer" checkbox. - Select the "Inter process" radio button. - Increase the timeout (sec) value to say 120. - Uncheck the "enable row buffer". - The timeout value is still 120. - Press OK to get back to the admin clients project tab. - Press OK buttons to fully exit the admin client. - Open the DataStage Administrator again. - On the admin clients project tab, select the required project, and press the properties button. - Select the "Tunables" tab. - The timeout value is reset to 10.
Local fix
Leave "enable row buffering" turned on.
Problem summary
**************************************************************** USERS AFFECTED: Administrators viewing Project Tunables **************************************************************** PROBLEM DESCRIPTION: Visiting Administrator->Project->Properties->Tunables and exiting without changing anything causes the IPCTimeout value inDSParams to be reset to 10 seconds, overwriting the value that was there before. This affects the value used in subsequent job runs and job compilations. **************************************************************** RECOMMENDATION: Apply patch This change is included in 8.0.1 Fix Pack 2. This change is included in 8.1 Fix Pack 1. ****************************************************************
Problem conclusion
Code was incorrectly overwriting and writing back the default value for IPCTimeout.
Temporary fix
Comments
APAR Information
APAR number
JR30413
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
801
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-09-05
Closed date
2008-09-18
Last modified date
2009-12-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CLIENT
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R801 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"IBM InfoSphere DataStage"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
15 December 2009