A fix is available
APAR status
Closed as program error.
Error description
When a bracket is initiated with a BID, then a subsequent FM Data RU is received needing a definite response, the RUI_WRITE issued to generate the positive response, although issued correctly, is modified internally to improperly set the DFC and FI flags in the RH header, causing the response to be rejected with an UNBIND with sense code 10020000 "RU Length Error".
Local fix
Problem summary
USERS AFFECTED: Applications using the RUI_PRIMARY LUA API. PROBLEM DESCRIPTION: Trace shows: SND>> BID RQD1 DFC FI BC EC <<RCV BID +RSP DFC FI SND>> FMD RQD1 FMD BB CD BC EC <<RCV FMD +RSP FMD <<RCV FMD RQD1 SND>> ? +RSP DFC FI <<RCV UNBIND RQD1 10020000 SND>> UNBIND +RSP PROBLEM SUMMARY: In an API trace, the application issues a RUI_WRITE with a correct +RSP to the FMD, but internal processing changes it to a DFC +RSP.
Problem conclusion
Code has been changed to correct the processing of the RUI_PRIMARY DFC responses.
Temporary fix
Comments
APAR Information
APAR number
LI81212
Reported component name
CS FOR LINUX
Reported component ID
5724I3300
Reported release
640
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-12-04
Closed date
2019-12-04
Last modified date
2019-12-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CS FOR LINUX
Fixed component ID
5724I3300
Applicable component levels
R640 PSY
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSHQLW","label":"Communications Server for Linux"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]