Error description
The ODR-DYN keyword is provided on the target_url to invoke a call on the url-open to DataPower's ODR library (ODRLIB). It reads in the host header and uri_path to determine where to route the request on the backend, liberty collective.
Local fix
temporary js script can be used as a workaround - not recommended for production
Problem summary
http://ODR-DYN was being folded to http://odr-dyn (lower case) whereas DataPower requires ODR-DYN to be in upper case.
Problem conclusion
Temporary fix
Comments
This issue is targeted for delivery in the next refresh pack of IBM API Connect. At the time of writing the current level is V5.0.4.0.
APAR Information
APAR number
LI79315
Reported component name
API CONNECT PRO
Reported component ID
5725Z2200
Reported release
502
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-10-12
Closed date
2016-11-01
Last modified date
2016-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
R502 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSMNED","label":"IBM API Connect"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"502","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]