IBM Support

OW35545: NSC HYPERCHANNEL FAILS TO ACTIVATE WITH TCP/IP V3.4 VTAM V4.1.1 EZZ4308I CODE=80103332 DIAG CODE 02 IST1578I SOFT INOP CODE 100

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When starting TCP/IP with NSC HyperChannel devices as gateway
    following message:
    EZZ4308I ERROR: CODE=80103332 DURING ACTIVATION OF DEVICE DXEA2.
    DIAGNOSTIC CODE: 02
    Also seen
    EZZ4202I OPENEDITION-TCP/IP CONNECTION ESTABLISHED FOR TCPIP
    EZZ4308I ERROR: CODE=80100041 DURING ACTIVATION OF DEVICE DXEA1.
    DIAGNOSTIC CODE: 02
    IST1578I SOFT INOP DETECTED FOR IUTH0140 BY ISTTCCTI CODE = 100
    IST1578I SOFT INOP DETECTED FOR IUTL4100 BY ISTTCCTA CODE = 101
    

Local fix

  • The HyperChannel device must be defined
    to MVS as either a CTC/SCTC or 3745 device.
    Because of the difference in UCB structures,
    2703 is not supported.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All TCP/IP Users of HYPERchannel DLC.        *
    ****************************************************************
    * PROBLEM DESCRIPTION: Either                                  *
    *                      EZZ4308I ERROR: CODE=80103332,          *
    *                      or                                      *
    *                      EZZ4308I ERROR: CODE=80100041           *
    *                      IST1578I SOFT INOP DETECTED FOR         *
    *                      IUTHnnnn BY ISTTCCTI CODE = 100         *
    *                      are seen during activation of           *
    *                      HYPERchannel devices.                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The first problem, with CODE=80103332 (the meaning
    of this IUTSTAFD code is "Invalid Channel ID")
    occurs when a TCP user of the HYPERchannel DLC
    attempts to activate a connection, and the
    HYPERchannel device is not defined to MVS as a CTC
    device. ISTINMAV fails the activation upon seeing
    that the UCBDVCLS field in the UCB does not match
    the value X'41'.
    
    In the second problem, with CODE=80100041, the
    HYPERchannel device is defined as a CTC device,
    so ISTINMAV validates its UCB and allocates
    the device. However, when the Initialization
    channel program is issued (a Sense Statistics
    CCW), an ATTention interrupt is received with
    either DeviceEnd+ControlUnitEnd (DE+CUE), or
    DE+CUE+Busy. The PUPAB interrupt handler, ISTTCCTI,
    does not recognize this as a valid CSW status, and
    it generates a connection INOP, failing the activation.
    

Problem conclusion

  • VTAM is changed to permit defining the HYPERchannel
    device as either a CTC device or as a 3745. These
    changes consist of having module ISTINMAV recognize
    either X'40' or X'41' as a valid value for the
    UCB device class. If the value is X'40', a specific
    set of device types is checked for in the UCBTBYT4
    field: X'15', X'25', or X'F1'. These three values
    are chosen because the UIMs provided by OS/390
    for these devices are the only ones that generate
    the device-dependent segment (IECDUCBE) for communications
    devices. This device-dependent segment is required
    by VTAM channel end appendage interface to support the
    device.
    
    The NSC Hyperchannel documentation recommends that
    the device be defined to MVS as either a 3705 or
    a 3745. Their suggested definitions are shown below:
    
    For the 3705:
    
     CNTLUNIT CUNUMBR=CCCC,
         PATH=PP,
         SHARED=N,
         UNIT=3705,
         UNITADD=((BB,NN)),
         PROTOCOL=S4,
         LINK=(SS),
         CUADD=(L)
    
    IODEVICE ADDRESS=(DDDD,NN),
        UNIT=BSC1,
        UNITADD=(BB,NN)
        ADAPTER=BSCA,
        TCU=270X,
        CUNUMBR=CCCC,
        PART=NAME
    
    For the 3745:
    
     CNTLUNIT CUNUMBR=CCCC,
         PATH=PP,
         SHARED=N,
         UNIT=3745,
         UNITADD=((BB,NN)),
         PROTOCOL=S4,
         LINK=(SS),
         CUADD=(L)
    
    IODEVICE ADDRESS=(DDDD,NN),
        UNIT=3745,
        UNITADD=(BB,NN)
        ADAPTER=CA1,
        CUNUMBR=CCCC,
        PART=NAME
    
    The 3705 definition (otherwise known as a 2703
    definition becuase of the TCU=270X parameter (where
    X can be 1,2,or 3) on the IODEVICE statement) cannot be
    supported by VTAM because the UIM for that device does
    not cause the UCB to contain the required device-dependent
    segment.
    
    Therefore, if a customer currently has a HYPERchannel device
    defined as a 3705 (TCU=270x) device, they must redefine
    it either as a 3745, as recommended by NSC, or as a CTC device.
    
    As part of the 3745 definition support, VTAM must provide
    its own ERP routine, so existing module ISTZBM0K is specified
    for that purpose, and is changed to support HYPERchannel as
    well as CDLC.
    
    Finally, ISTTCCTA is changed to ignore the DE+CUE and DE+CUE+BSY
    conditions during the initialization phase. These are transient
    conditions that are followed by CE+DE.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OW35545

  • Reported component name

    VTAM V4 MVS/ESA

  • Reported component ID

    569511701

  • Reported release

    411

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    1998-10-02

  • Closed date

    1999-03-05

  • Last modified date

    1999-04-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UW57052 UW57053 UW57054

Modules/Macros

  • ISTINMAV ISTTCCTA ISTZBM0K
    

Fix information

  • Fixed component name

    VTAM V4 MVS/ESA

  • Fixed component ID

    569511701

Applicable component levels

  • R411 PSY UW57052

       UP99/03/19 P F903

  • R501 PSY UW57053

       UP99/03/19 P F903

  • R701 PSY UW57054

       UP99/03/19 P F903

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"411","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCY4DZ","label":"DO NOT USE"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"411","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
05 April 1999