A fix is available
APAR status
Closed as program error.
Error description
Miscellaneous fixes for ATF
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All OMEGAMON for IMS on z/OS users * **************************************************************** * PROBLEM DESCRIPTION: * * 1. ATF takes >3 minutes to terminate. * * * * 2. Missing extended DLI call information * * on ATF panels for an FP DB call made * * from a CICS application. * * 3. Slow response when viewing ATF * * Application Trace Summary. * * 4. ATF records lack an indicator of * * Exception which is needed by IMSPA and * * other tools to process records extracted * * from ATF Detail logstream. * * * * 5. ATF does not report 3rd-party ESS * * calls correctly. * **************************************************************** * RECOMMENDATION: * * Apply this PTF * **************************************************************** 1. ATF Task Controller routine corrupts the pointer to a control block referenced at ATF shutdown. 2. ATF Data Collector uses an incorrect pointer to access the DLI parmlist for a DBT thread. 3. ATF logstream reader routine lacks the logic to limit the record-set scope when reading backwards. 4. As the ATF Exception Detail logstream no longer exists in v550, the Detail logstream now contains both the exception and non-exception records but there is no way to tell them apart without first reading the Summary logstreams. 5. ATF does not support 3rd-party ESS calls.
Problem conclusion
1. ATF Task Controller routine has been corrected to restore the pointer. 2. ATF Data Collector has been corrected to use the appropriate DLI parmlist. 3. Logic has been added in ATF logstream reader routine to use the trace start timestamp as the end of record-set. 4. Flags have been defined in ATF records to indicate an Exception and Exception-Only. Refer to member KI2ATFSM in your <rte>.TKANSAM library. 5. Support for 3rd-party ESS calls has been added. ADDITIONAL KEYWORDS: EDP SQDATA ATVS ATVW ATVD KIPATFTE KIPATFAP
Temporary fix
Comments
APAR Information
APAR number
OA54667
Reported component name
OM XE FOR IMS Z
Reported component ID
5698A3900
Reported release
550
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-01-11
Closed date
2018-01-19
Last modified date
2018-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA95054
Modules/Macros
KI2MN0M0 KI2MN0N0 KI2MN0O0 KI2MN0P0 KI2AJW00 KI2NR000 KI2ARZ00 KOIAM000 KI2BS000 KI2TE000
Fix information
Fixed component name
OM XE FOR IMS Z
Fixed component ID
5698A3900
Applicable component levels
R550 PSY UA95054
UP18/01/25 P F801
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXS8U","label":"Tivoli OMEGAMON XE for IMS on z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"550","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
01 February 2018